Noise Figure Options Summary - Keysight Technologies N5249A Configuration Manual

Pna-x series pna series pna-l series n522x/3x/4xa microwave network analyzers
Hide thumbs Also See for N5249A:
Table of Contents

Advertisement

PNA Family Application Options,

Noise figure options summary

Overview
Description
Required options
Includes low-noise receivers
Includes filters for LO-harmonic
rejection
Includes source tuner bypass switch
Use standard receivers for noise
figure measurements
2
Vector noise calibration available
using ECal as tuner
Vector noise calibration using built-in tuner
Recommended ECal for vector
noise calibration
3
Included tuner accessories for m-f ECal
Recommended adapter for f-f ECal tuner
(N4691B/93A/94A-00F)
Scalar noise calibration available
S-parameter, conversion gain/loss
measurements
Max freq (GHz)
NF measurements, amplifiers
Max frequency, using low-noise
receivers (GHz)
Max frequency, using standard
receivers (GHz)
2
Calibration accessories for low-noise
receivers
Calibration accessories for standard
receivers
NF measurements, converters
Max input frequency (GHz)
Max output frequency, using low-noise
receivers (GHz)
Max output frequency, using standard receivers (GHz)
Calibration accessories for low-noise receivers
Calibration accessories for standard receivers
1
For N5247A, the low-noise receiver works up to 50 GHz only.
2
External preamplifier and filter(s) required if DUT excess noise (gain plus noise figure) is < 30 dB up to 20 GHz, < 40 dB up to 50 GHz, or < 45 dB up to 67 GHz.
3
Only N4690 Series ECal modules are supported for use as an impedance tuner.
Find us at www.keysight.com
continued
Option 028
Noise figure application using standard receivers only, for
all PNA / PNA-X models.
080, and 082 or 083 for measuring frequency converters. Not
available with N522xA-200 and -400.
No
No
No
Yes
Yes
No
3.5 mm N4691B-M0F (N5221/22/41/42/49A)
2.4 mm N4693A-M0F (N5224/25/44/45A)
1.85 mm N4694A-M0F (N5227/47A)
3.5 mm N5242-20137 cable, 85052-60013 m-f adapter
(N5221/22/41/42/49A)
2.4 mm N5245-20140 cable, 85056-60007 m-f adapter
(N5224/25/44/45A)
1.85 mm N5247-20142 cable, 85058-60115 m-f adapter
(N5227/47A)
3.5 mm 85052-60014 m-m adapter (N5221/22/41/42/49A)
2.4 mm 85056-60005 m-m adapter (N5224/25/44/45A)
1.85 mm 85058-60113 m-m adapter (N5227/47A)
Yes
8.5/13.5/26.5/43.5/50/67
N/A
8.5/13.5/26.5/43.5/50/67
N/A
Cal kit or ECal, power meter
8.5/13.5/26.5/43.5/50/67
N/A
18.5/13.5/26.5/43.5/50/67
2
N/A
Cal kit or ECal, power meter
Option 029
Noise figure application using standard or low-noise
receivers, for all PNA-X models.
For N5241/42/49A, 080 and either 219, 224, 419, 423, or
H85. For N5244/45/47A, 080 and either 224 or 423.
For measuring frequency converters, requires Option 082
or 083.
Yes
1
Yes
1
Yes
Yes
Yes
Yes, for N5244/45/47A
3.5 mm N4691B-M0F (N5241/42/49A)
Built-in for N5244/45/47A
3.5 mm N5242-20137 cable, 85052-60013 m-f adapter
(N5241/42/49A)
N/A for N5244/45/47A, due to built-in tuner
3.5 mm 85052-60014 m-m adapter (N5241/42/49A)
N/A for N5244/45/47A, due to built-in tuner
Yes
8.5/13.5/26.5/43.5/50/67
8.5/13.5/26.5/43.5/50
8.5/13.5/26.5/43.5/50/67
Cal kit or ECal, 346C or 346C-K01 noise source or power
meter
Cal kit or ECal, power meter
8.5/13.5/26.5/43.5/50/67
8.5/13.5/26.5/43.5/50/67
8.5/13.5/26.5/43.5/50/67
Cal kit or ECal, power meter, 346C or 346C-K01 noise
source (optional)
Cal kit or ECal, power meter
Page 18