Parameters Table - PENSOTTI PNCC-32N Instruction Manual

Wall mounted combination space heating & dhw boiler
Table of Contents

Advertisement

5. REGULATING THE BOILER

5.1 Parameters table

PARAMETER
P00
P01
Selects the type of gas supply
P02
Sets the central heating temperature
Water hammer delay function
(Not applicable to only heating
P03
P04
P05
Central heating pump overrun timer
D.H.W./ storage cylinder pump overrun
(Not applicable to instantaneous
P06
boilers w/dual circuit exchanger and
P07
P08
P09
(Not applicable to instantaneous
P10
boilers w/dual circuit exchanger and
Legionella prevention function
P11
Sets the climatic compensation curve
P12
(w/outdoor temperature sensor only
P13
Central heating minimum Set Point
Central heating maximum Set Point
P14
P15
(Not applicable to only heating
P16
(Not applicable for open chamber
INSTALLATION INSTRUCTIONS
TYPE OF OPERATION
Selects the type of boiler
boilers)
Central heating timer
timer
only heating boilers)
Minimum BTU output
Maximum BTU output
Sets the ignition sequence
D.H.W. priority function
only heating boilers)
(For storage boilers only)
installation)
D.H.W maximum Set Point
boilers)
Post ventilation
models)
PARAMETER
VALUE
00 = NA
01 = PNCC
02 = PNCH
00-05
03 = NA
04 = NA
05 = PNCH -NO Indrect Water Heater
00
01
00
01
0 - 20
Displayed in multiples of 5 seconds
00-90
(default value 36 x 5 = 180")
Displayed in multiples of 5 seconds
00-90
(default value 36 x 5 = 180")
Displayed in multiples of 5 seconds
00-90
00 - Max (P08)
Min (P07) - 99
00-99
(default = 50)
00
01
00
01
See the graph in the parameter setting
00-30
68 - 104
104 - 185
113 - 167
00 - 10
FUNCTION
Natural gas
LPG
Standard (95-185°F)
Reduced (77-113°F)
Displayed in Seconds
Defalt = 0
(default value 18 x 5 = 90")
Displayed in %
Displayed in %
Displayed in %
Off
On
Off
On
explanation
Displayed in °F
Displayed in °F
Displayed in °F
Displayed in minutes
52