INSTALLATION INSTRUCTIONS
P
P05 - C
ARAMETER
ENTRAL HEATING PUMP OVERRUN TIMER
This parameter is used to set the pump functioning time, in heating mode, after
switching off the main burner for the intervention of the room thermostat.
To enter the parameters menu, follow the previously described procedure (see
paragraph 5.2 'Accessing the parameters menu' - steps 1-5).
. Use '
' and '
' buttons (D.H.W temperature setting)
6
value of the parameter within the prescribed limits
):
seconds
min = 00
max = 90
For ex.:
90 = 90 x 5 = 450 seconds (7.5 min)
The default value is 36 = 180 seconds (3 min)
7.
Press mode selection button
adjustment operative
.
display
.
To exit from the parameters menu, press simultaneously '
8.
.
buttons
P06 – D.H.W./STORAGE CYLINDER PUMP OVERRUN TIMER
P
ARAMETER
(Not applicable to instantaneous boilers w/dual circuit exchanger)
This parameter is used to set the pump functioning time, in D.H.W mode, after
closing the water tap.
To enter the parameters menu, follow the previously described procedure (see
paragraph 5.2 'Accessing the parameters menu' - steps 1-5).
Use '
' and '
' buttons (D.H.W temperature setting)
6.
value of the parameter within the prescribed limits
(
Displayed in multiples of 5 seconds
min = 00
max = 90
For ex.:
90 = 90 x 5 = 450 seconds (7.5 min)
The default value is 18 = 90 seconds (1.5 min)
7.
Press mode selection button
adjustment operative
.
display
.
To exit from the parameters menu, press simultaneously '
8.
.
buttons
'
'
to confirm and to render the new
The parameter number (P05) will appear on the
:
):
'
' '
to confirm and to render the new
The parameter number (P06) will appear on the
to modify the
(
displayed in multiples of 5
' and '
to modify the
' and '
'
'
56