Download Print this page

PENSOTTI SOLENNE SERIES User Manual

Wall mounted premix condensing boiler

Advertisement

Quick Links

User Manual
SOLENNE SERIES
Wall mounted
premix condensing boiler
If you smell gas ...
DO NOT ACTIVATE ANY ELECTRIC SWITCHES, TELEPHONES OR ANY OTHER DEVICE THAT MAY
GENERATE ELECTRICAL DISCHARGES OR SPARKS.
OPEN DOORS AND WINDOWS IMMEDIATELY TO CREATE A CURRENT OF AIR THAT WILL RAPIDLY
CLEAR THE ROOM.
CLOSE ALL GAS TAPS AND VALVES.
CALL FOR PROFESSIONALLY QUALIFIED PERSONNEL FROM A NEAR BY TELEPHONE.
User instructions
ENGLISH

Advertisement

loading

Summary of Contents for PENSOTTI SOLENNE SERIES

  • Page 1 User Manual SOLENNE SERIES Wall mounted premix condensing boiler If you smell gas … DO NOT ACTIVATE ANY ELECTRIC SWITCHES, TELEPHONES OR ANY OTHER DEVICE THAT MAY GENERATE ELECTRICAL DISCHARGES OR SPARKS. OPEN DOORS AND WINDOWS IMMEDIATELY TO CREATE A CURRENT OF AIR THAT WILL RAPIDLY CLEAR THE ROOM.
  • Page 3: General Warnings

    USER INSTRUCTIONS BOILER OPERATING INSTRUCTIONS Make sure that the authorized technician who tested the boiler has documented the test results including gas pressure, CO2, flue gas temperature and safety device functions. The installation, first start-up, regulation and maintenance operations must be carried out by qualified personnel. Incorrect installation or maintenance can cause damage to property and injury to persons or animals, for which the manufacturer will not be held responsible.
  • Page 4 USER INSTRUCTIONS If you smell gas … DO NOT ACTIVATE ANY ELECTRIC SWITCHES, TELEPHONES OR ANY OTHER DEVICE THAT MAY GENERATE ELECTRICAL DISCHARGES OR SPARKS. OPEN DOORS AND WINDOWS IMMEDIATELY TO CREATE A CURRENT OF AIR THAT WILL RAPIDLY CLEAR THE ROOM. CLOSE ALL GAS TAPS AND VALVES.
  • Page 5: Starting - Up The Boiler

    USER INSTRUCTIONS Starting - up the boiler • Open the gas Isolation valve located under the boiler. • Switch on the boiler by placing the ON/OFF switch (1) in the ON position (see “Control panel”). • The boiler will light automatically (with the WINTER mode selected and room thermostat connected).
  • Page 6: Diagnostics - Error Codes

    USER INSTRUCTIONS ■ D.H.W temperature control The domestic hot water temperature is regulated by knob 3 (see “Control panel”). • Rotating the knob counter-clockwise reduces the temperature. • Rotating knob clockwise increases temperature. • The range of temperature settings for the domestic hot water runs from a minimum of 95°F to a maximum of 160°F.
  • Page 7 USER INSTRUCTIONS _E05_ Heating Sensor malfunction Code E05 lit continuously on the display. Call for Service. _E12_ D.H.W Storage Cylinder Sensor Malfunction Code E12 lit continuously on the display. Call for Service. _E16_ Electric Fan Malfunction Code E16 lit continuously on the display. Call for Service. _E22_ Parameter programming request Code E22 lit continuously on the display.