PENSOTTI PNCC-32N Instruction Manual

Wall mounted combination space heating & dhw boiler

Advertisement

Instruction Manual
Installer: Affix these instructions adjacent to the boiler
Homeowner: Retain these instructions for future reference
PNCC-32N
(Natural Gas)
PNCC-32P
(LPG)
Wall mounted combination space heating & DHW boiler
WARNING
If the information in these instructions is not followed exactly, a fire or explosion may
result, causing property damage, personal injury or death.
• Do not operate this appliance without the front cover properly secured.
• Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other
appliance.
• WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance
• Do not touch any electrical switch; do not use any phone in your building
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department
• Installation and service be performed by a qualified installer, service agency or the gas supplier.
• This appliance REQUIRES an annual maintance, service and inspection by a qualified service technician.
• Use of a properly calibrated electronic combustion analyzer MUST be used to install and/or service this
appliance.
Approved in accordance with:
ANSI Z21.13b-2010 / CSA 4.9b (2010) Low Pressure Boiler
Manufactured/Distributed by : Granby Furnaces Inc.
12118 Hwy 209, Parrsboro, NS, Canada

Advertisement

Table of Contents
loading

Summary of Contents for PENSOTTI PNCC-32N

  • Page 1 Instruction Manual Installer: Affix these instructions adjacent to the boiler Homeowner: Retain these instructions for future reference PNCC-32N (Natural Gas) PNCC-32P (LPG) Wall mounted combination space heating & DHW boiler WARNING If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal injury or death.
  • Page 2: Table Of Contents

    CONTENTS Pages 1. General information General warnings Product conformity 2. Technical characteristics Technical data Dimensions Internal parts of the boiler Water circuit Circulation pump head/flow graph Printed circuit board – Technical characteristics Control panel INFO Menu display 3. Installation (authorized personnel) Reference standard Unpacking Installation boiler...
  • Page 3 CONTENTS Pages 6. Maintenance (authorized personnel) General warnings Boiler inspection Accessing the boiler Flushing out the primary side Draining the central heating and domestic hot water system Wiring diagrams Electrical connections (Option) Troubleshooting Function codes 6.10 Parts list – Exploded Drawings WARRATY INFORMATION...
  • Page 4: General Information

    The appliance should be located in an area where leakage within the unit or at its connections will not result in damage to the area adjacent to the appliance or to lower floors of the structure. PENSOTTI will not be responsible for any damage resulting from leaking if adequate drainage is not provided. When such locations cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be installed under the appliance.
  • Page 5 Check the Rating Plate PENSOTTI units come from the factory configured for use with either LP or Natural Gas. Prior to installation, check the rating plate of the boiler to ensure the unit matches gas type, gas pressure, water pressure and electrical supply.
  • Page 6 Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Pressures in excess of 14”WC may damage the internal components of this boiler. Pensotti REQUIRES replacment of the gas valve if it is subjected to pressures in excess of 14”WC. Faliure to comply could cause dangerous operating conditions, fire, explosion, bodily injury or possible death.
  • Page 7 Many jurisdictions require the installation of carbon monoxide detectors in building where a side wall vented fuel burning appliance is installed. Installers must abide by local code requirements regarding the installation of CO detectors. The use of a certified carbon monoxide detector is recommended but not required by PENSOTTI. “In the State of Massachusetts only”...
  • Page 8 GENERAL INFORMATION...
  • Page 9 GENERAL INFORMATION...
  • Page 10 GENERAL INFORMATION...
  • Page 11 GENERAL INFORMATION...
  • Page 12: Product Conformity

    GENERAL INFORMATION 1.2 Product conformity All Granby/Pensotti LLC boilers are ETL certified and possess technical and functional characteristics that comply with the following standards: Gas fired Low Pressure Hot Water Boiler: American National Standard/CSA Standard for Gas Fired Low Pressure Steam and Hot W ater Boiler .
  • Page 13: Technical Characteristics

    INSTALLATION INSTRUCTIONS 2. TECHNICAL CHARACTERISTICS 2.1 Technical data Model PNCC-32 Appliance Type II2H3+ Appliance Category C12 - C32 - C42 - C52 - C62 - C82 BTU/hr NG/LP 110,000 / 100,000 Heat Input max Heat Input min BTU/hr NG/LP 68,000 / 68,000 Heat Output max BTU/hr NG/LP 92,400 / 84,000...
  • Page 14: Dimensions

    INSTALLATION INSTRUCTIONS 2.2 Dimensions...
  • Page 15: Internal Parts Of The Boiler

    INSTALLATION INSTRUCTIONS 2.3 Internal parts of the boiler...
  • Page 16: Water Circuit

    INSTALLATION INSTRUCTIONS 2.5 Water circuit...
  • Page 17: Circulation Pump Head/Flow Graph

    INSTALLATION INSTRUCTIONS 2.5 Circulation pump head/flow graph...
  • Page 18: Printed Circuit Board - Technical Characteristics

    INSTALLATION INSTRUCTIONS ® 2.6 DIGITECH TR Printed Circuit Board (MIAH403) Technical characteristics Adjustments for service personnel only  Standard (95-185°F) / reduced (77-113°F) central heating temperature  Water hammer delay function  Central Heating timer - (adjustable from 0 to 7.5 minutes) ...
  • Page 19: Info Menu Display

    INSTALLATION INSTRUCTIONS LCD DISPLAY ICONS’ KEY PARAMETER NUMBER INFORMATION PARAMETERS PROGRAMMING MODE ON SOLAR PCB CONNECTION INFORMATION / SOLAR PANEL TEMPERATURE DISPLAY (d6) SOLAR PUMP ON SOLAR STORAGE CYLINDER LOW LEVEL TEMPERATURE VISUALIZATION (d7) / STORAGE CYLINDER HIGH LEVEL TEMPERATURE VISUALIZATION (d8) OUTDOOR TEMPERATURE SENSOR CONNECTED TEMPERATURE / SET POINT / PARAMETER...
  • Page 20: Installation (Authorized Personnel)

    INSTALLATION INSTRUCTIONS 3. INSTALLATION (authorized personnel) 3.1 Reference standard Install in accordance with local building and electrical codes. Failure to install a gas appliance correctly and in accordance with the above codes could lead to prosecution. It is in the best interest of the installer and for safety reasons that all applicable codes are complied with. The manufacturer’s instructions form an integral part of the installation and should be left with the appliance but do not override in anyway statutory obligations.
  • Page 21: Unpacking

    (Be sure to secure all of these items before discarding any packing material) STORAGE & HANDLING Please note that prior to installation the Pensotti LLC boilers should be stored in the horizontal position with no more than three boilers to a stack;...
  • Page 22: Installation Boiler

    INSTALLATION INSTRUCTIONS 3.3 Installing the boiler The appliance must be installed exclusively on a plumb, vertical solid wall capable of supporting its weight. ■ The boiler should be fitted within the building unless otherwise protected by a suitable heated enclosure i.e. garage or outhouse. (The boiler may be fitted inside a cupboard) ■...
  • Page 23: Water Connections

    INSTALLATION INSTRUCTIONS 3.4 Water connections In order to safeguard the heat exchanger and circulation pump, especially in case of appliance replacement, it is recommended that the system is hot-flushed to remove any impurities (especially oil and grease) from the pipes and radiators. In order to safeguard all waterside components the supplied Fernox Commissioning Kit MUST be used in its...
  • Page 24 INSTALLATION INSTRUCTIONS Domestic Hot Water Relief Valve (If Required by code) Jurisdictions may require the installation of a 150# pressure relief valve on the domestic hot water piping of this boiler. If so, the picture below is a suggested method of installation. Always refer to and follow all applicable federal, state and local codes along with the relief valve manufacturers’...
  • Page 25: Piping Diagrams - Piping Information

    INSTALLATION INSTRUCTIONS 3.5 Piping Diagrams Preferred piping methods (primary-secondary) Alternate piping method...
  • Page 26 (contact your boiler distributor for assistance). Dirt / Scale Seperation Along with the application of our Fernox commisioning kit Pensotti highly recommends the installation of a dirt seperator in the return piping of all Solenne Series boiler models. Follow the manufacturers instructions when...
  • Page 27 INSTALLATION INSTRUCTIONS Central heating circuit Pensotti requires the installation of a pressure reducing valve & backflow preventor with all Solenne Series boilers. In order to prevent scaling or deposits in the primary heat exchanger, the main supply water to the heating circuit must be treated according to the requirements of local standards.
  • Page 28: Gas Connection

    Until pressure testing of the main gas supply line is completed, ensure the gas line to the PENSOTTI Boiler is disconnected to avoid any damage to the boiler.
  • Page 29 INSTALLATION INSTRUCTIONS Natural Gas Pipe Sizing Chart Size of Schd. 40 Black Iron Pipe in Inches Length of Pipe In Feet 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 1237 2259 1610 1335 1143 1041 Natural Gas flow is given in thousands of BTU/hr. - One cubic foot of natural gas = 1000 BTU Nominal pressure at the burner for Natural Gas is 3.5"...
  • Page 30: Electrical Connections

    Damage caused by excessive voltage is not covered under warranty. DO NOT connect 220-240VAC to this PENSOTTI Boiler. This will damage the boiler and void the warranty. Do not disconnect the power supply when the unit is in normal operation.
  • Page 31 INSTALLATION INSTRUCTIONS Always check to make sure that the appliance has an efficient earth ground system. This requirement is only satisfied if it has been properly connected to an efficient ground system installed in accordance with the requirements of current safety standards and carried out by professionally qualified personnel. This basic safety measure must be checked, verified and carried out by professionally qualified personnel.
  • Page 32 INSTALLATION INSTRUCTIONS Electrical Connections Connect the power supply to the terminal board inside the control panel as follows: a. Switch off the power supply at service switch or breaker. b. Remove the front case panel of the boiler. c. Loosen the screws and remove plate A (see fig. 1). d.
  • Page 33: Venting Connections

    When CVS is used as a concentric/direct vent system on gas and installed on a Pensotti Solenne CLASSIC boiler, clearance to combustibles is 0” . Never fill any required clearance space with insulation or any other materials.
  • Page 34 • Consider the length of horizontal runs, Connect CVS vent pipe to the appliance adapter elbows, clearance requirements, and location Pensotti Part #: PA50-00137 via the DuraVent of terminations. Part #: 35CVS-AD-PS. • For horizontal vent runs, maintain at least a ¼”...
  • Page 35 INSTALLATION INSTRUCTIONS...
  • Page 36 INSTALLATION INSTRUCTIONS Determine the venting path required for your (d) Clearance to an unventilated soffit: installation. There are two general types of 24 inches minimum. installations: Horizontal Installations, and (e) Clearance to an outside corner: 12 inches minimum Vertical Installations. (f) Clearance to an inside corner: 36 inches minimum Refer to Figure 2 for some typical installations.
  • Page 37 INSTALLATION INSTRUCTIONS 3. Cut wall penetration. Refer to the appliance manufacturer for clearance to combustible requirements from the vent. To accommodate the flared end of the vent pipe, the minimum hole size should be 5-3/8” x 5-3/8” for a square cut, or 5-3/8” diameter for a round cut (Fig 5).
  • Page 38 INSTALLATION INSTRUCTIONS Vertical Installation: If the vent pipe is to pass through a cold attic space. Vent pipe MUST be insulated with the proper insulation material. 1. Install Appliance. Determine where your appliance will be installed and follow the Appliance manufacturer’s installation instructions accordingly.
  • Page 39 INSTALLATION INSTRUCTIONS 5. Install CVS Vent Pipe. If your appliance After the Flashing is installed, wrap the Storm Collar around the vent pipe, inserting the tab and folding it requires an Appliance Adapter, install it onto back to secure the collar tightly the appliance.
  • Page 40 INSTALLATION INSTRUCTIONS MAINTENANCE Conduct an inspection of the venting system semiannually. Recommended areas to inspect are as follows: 1. Check areas of the Venting System which are exposed to the elements for corrosion. These will appear as rust spots or streaks, and in extreme cases, holes.
  • Page 41 INSTALLATION INSTRUCTIONS 36”...
  • Page 42 INSTALLATION INSTRUCTIONS Description Order No. 1.51 & 1.61” FLUE DIAPHRAM Exhaust Flue Diaphrams Boiler Vent Adapter w/ Test Ports PA50-00137 CVS Adapter PA35CVS-AD-PS 90° Elbow PACVS-E90 12” Vent Pipe PACVS-12 8-13” Horizontal Termination PACVS-HCR Wind Guard PACVS-HG Inner Trim Ring PACVS-TRI OutterTrim Ring PACVS-TRO...
  • Page 43 INSTALLATION INSTRUCTIONS...
  • Page 44 INSTALLATION INSTRUCTIONS IMPORTANT Secure boiler adapter to the DuraVent CVS adapter with 2 qty - ½” screws. (not provided). Rough in dimension of coaxial vent pipe is approx. 13” from the top of the boiler to the center line of the CVS vent pipe.
  • Page 45 INSTALLATION INSTRUCTIONS...
  • Page 46 INSTALLATION INSTRUCTIONS Exhaust flue pipe condensate drain The Pensotti boiler adapter is supplied with a ½” Male IPS condensate drain attachment. Some flue pipe installations such as those of extended lengths or installed in cold environments may produce excessive amounts of condensate.
  • Page 47 INSTALLATION INSTRUCTIONS Important! Creat a condensate trap as pictured above by making a minimum 8” diameter loop in the tubing. This condensate loop trap is required to eliminate the possibility of flue gases entering the home. Before firing the boiler fill the trap with water. Please folow all applicable local, state and national codes in regards to condensate disposal.
  • Page 48 INSTALLATION INSTRUCTIONS 3.10 Diaphragms system setting  Horizontal-Concentric flue system with intake / exhaust pipes Ø3/5in FLUE DIAPHRAGM EXHAUST MAXIMUM FLUE LENGTH FLUE DIAPHRAGM EXHAUST (linear length) INSTALL THE FLUE DIAPHRAGM Ø from 3.2 to 6.5 ft 1.51 in ON THE FLUE EXHAUST HOLE INSTALL THE FLUE DIAPHRAGM Ø...
  • Page 49 INSTALLATION INSTRUCTIONS Refer to twin pipe venting instruction supplied with DuraVent twin pipe venting material.  2 pipes non concentric flue system (flue and air intake) Ø3/3in MAXIMUM FLUE LENGTH FLUE DIAPHRAGM INTAKE FLUE DIAPHRAGM EXHAUST (linear length) INSTALL THE INSTALL THE from 3.2 + 3.2 to 13.1 + 13.1 ft FLUE DIAPHRAGM Ø...
  • Page 50: Commissioning The Appliance (Authorized Personnel)

    INSTALLATION INSTRUCTIONS 4. COMMISSIONING THE APPLIANCE 4.1 General warnings The following operations must be carried out by professionally qualified personnel, registered in accordance with current legislation. Use of a properly calibrated electronic combustion analyzer MUST be used when installing, servicing or converting this Boiler from Natural Gas to LP or from LP to Natural Gas.
  • Page 51: Filling The System

    If, after the above operations, there is a reduction in the pressure refill this system as directed above.  Pensotti recommends the installation of an automatic pressure reducing valve with backflow preventer installed in the proper location within the heating system. Adjust it to maintain a minimum water pressure of 14.5 psi or as...
  • Page 52: Flushing The System

    All systems must be thoroughly drained and flushed using additives – corrosion inhibitors and flushing agents/descalers. Pensotti requires the use of the supplied Fernox Commissioning Kit or individual containers of Fernox F3 or F5 cleaner and F1 protector. Follow Fernox installation instructions. Failure to use Fernox F3 or F5 cleaner and F1 protector will void the warranty for all waterside components.
  • Page 53: Starting Up The Boiler

    INSTALLATION INSTRUCTIONS 4.4 Starting up the boiler – Requires a Gas Manometer & Electronic Combustion Analyzer Once the system has been filled, purged of air, the gas line checked for leaks and venting system inspected proceed follows:  Check that the exhaust duct is free from obstructions and correctly connected to the flue exhaust system.
  • Page 54 Pressures in excess of 14”WC may damage the internal components of this boiler. Pensotti REQUIRES replacment of the gas valve if it is subjected to pressures in excess of 14”WC. Faliure to comply could cause dangerous operating conditions, fire, explosion, bodily injury or possible death.
  • Page 55: Parameters Table

    INSTALLATION INSTRUCTIONS 5. REGULATING THE BOILER 5.1 Parameters table PARAMETER PARAMETER TYPE OF OPERATION FUNCTION N° VALUE 00 = NA 01 = PNCC Selects the type of boiler 02 = PNCH 00-05 03 = NA 04 = NA 05 = PNCH -NO Indrect Water Heater Natural gas Selects the type of gas supply Standard (95-185°F)
  • Page 56: Accessing The Parameters Menu

    INSTALLATION INSTRUCTIONS 5.2 Accessing the parameters menu To modify the pre-set values of the parameters reported in the previous table, open the parameter settings menu as follows: 1. Place mode selection button ‘ ’ in OFF position, indicated symbol; 2. Keep pressed ‘ ’...
  • Page 57: Setting The Parameters

    INSTALLATION INSTRUCTIONS 5.3 Setting the parameters P00 – ARAMETER SELECTS THE TYPE OF BOILER To enter the parameters menu, follow the previously described procedure (see paragraph 5.2 ‘Accessing the parameters menu’ - steps 1-5). 6. Use ‘ ’ and ‘ ’...
  • Page 58 INSTALLATION INSTRUCTIONS P03 - W ARAMETER ATER HAMMER PREVENTION FUNCTION Activating this function, the D.H.W contact is delayed. To enter the parameters menu, follow the previously described procedure (see paragraph 5.2 ‘Accessing the parameters menu’ - steps 1-5). 6. Use ‘ ’...
  • Page 59 INSTALLATION INSTRUCTIONS P05 - C ARAMETER ENTRAL HEATING PUMP OVERRUN TIMER This parameter is used to set the pump functioning time, in heating mode, after switching off the main burner for the intervention of the room thermostat. To enter the parameters menu, follow the previously described procedure (see paragraph 5.2 ‘Accessing the parameters menu’...
  • Page 60 INSTALLATION INSTRUCTIONS P07 - M ARAMETER INIMUM OUTPUT 12. Enter the parameters menu and select parameter P07. The pressure gauge will indicate the gas pressure. If this pressure value is different to that on the rating plate of the boiler (see paragraph 5.5 ‘Gas Data’), use ‘...
  • Page 61 INSTALLATION INSTRUCTIONS P08 - M BTU O ARAMETER AXIMUM UTPUT To enter the parameters menu, follow the previously described procedure (see paragraph 5.2 ‘Accessing the parameters menu’ - steps 1-5). Select parameter P08. 6. Use ‘ ’ and ‘ ’ buttons (D.H.W temperature setting) adjust the value of the parameter from ‘99’...
  • Page 62 INSTALLATION INSTRUCTIONS P09 – S ARAMETER ETS THE IGNITION SEQUENCE This parameter is used to set the gas pressure during the starting up of the boiler. To enter the parameters menu, follow the previously described procedure (see paragraph 5.2 ‘Accessing the parameters menu’ - steps 1-5). 6.
  • Page 63 INSTALLATION INSTRUCTIONS P12 – SETS ARAMETER THE CLIMATIC COMPENSATION CURVE (w/outdoor temperature sensor only installation) The installation of an outdoor temperature sensor (see paragraph 6.7 ‘Electrical connections’) allows to automatically modify the flow temperature in accordance to the outdoor temperature. The factor governing the correction is the Kd thermoregulation value, indicating the flow temperature range selected (fig.
  • Page 64 INSTALLATION INSTRUCTIONS P13 – C ARAMETER ENTRAL HEATING INIMUM ET POINT This parameter is used to set the central heating minimum user set point. To enter the parameters menu, follow the previously described procedure (see paragraph 5.2 ‘Accessing the parameters menu’ - steps 1-5).
  • Page 65 INSTALLATION INSTRUCTIONS P15 – D. ARAMETER MAXIMUM SET POINT This parameter is used to set the D.H.W maximum user set point. To enter the parameters menu, follow the previously described procedure (see paragraph 5.2 ‘Accessing the parameters menu’ - steps 1-5). 6.
  • Page 66: Gas Data

    4.04 10.2 Pressures in excess of 14”WC may damage the internal components of this boiler. Pensotti REQUIRES replacment of the gas valve if it is subjected to pressures in excess of 14”WC. Faliure to comply could cause dangerous operating conditions, fire, explosion, bodily injury or possible death.
  • Page 67: Converting The Boiler To A Different Gas Type

    INSTALLATION INSTRUCTIONS 5.5 Converting the boiler to a different gas type KEY: GAS VALVE MODULATOR INLET PRESSURE POINT OUTLET PRESSURE POINT GAS PIPE BURNER MANIFOLD 17 RAMPS GAS BURNER INJECTORS IGNITION ELECTRODES FLAME IONISATION ELECTRODES MANIFOLD FIXING SCREWS Fig. 1 MODULATOR NUT The conversion of a boiler from burning natural gas to LPG, or vice versa, must be carried out exclusively by professionally qualified personnel, registered in accordance with current legislation.
  • Page 68: Maintenance (Authorized Personnel)

    (authorized personnel) 6.1 General Warnings All maintenance operations must be carried out by professionally qualified personnel, authorised by Granby/Pensotti LLC. The frequency of boiler maintenance must comply with current law and, nevertheless, should be carried out once a year. In order to guarantee the long life of the appliance and in accordance with the current gas safety regulations,...
  • Page 69: Accessing The Boiler

    INSTALLATION INSTRUCTIONS 6.3 Accessing the boiler All maintenance operations require one or more of the boiler casing panels to be removed. The side panels can only be removed after the front panel has been removed. Front panel:  Remove the fixing screws at the lower edge of the front panel.
  • Page 70: Draining The Central Heating And Domestic Hot Water System

    System winterization (non-operative system) Because it may be impossible to completely drain the boilers heating circuit, D.H.W circuit and distribution system. Pensotti recommends the introduction of the proper type antifreeze to protect these systems from freezing damage. System winterization (operating system) Pensotti boilers are certified for indoor use ONLY.
  • Page 71: Wiring Diagrams

    MAINTENANCE INSTRUCTIONS 6.6 Wiring diagrams – DIGITECH ® TR Printed Circuit Board (MIAH403) 110 V 60 hz...
  • Page 72: Electrical Connections (Option)

    MAINTENANCE INSTRUCTIONS 6.7 Electrical connections (Option) Connect the power supply to the terminal board located on the control panel as follows: a. switch off the power supply at the main switch; b. remove the front case panel of the boiler. (see paragraph ‘6.3 Accessing the boiler’); c.
  • Page 73: Troubleshooting

    MAINTENANCE INSTRUCTIONS 6.8 Troubleshooting - To display the last 5 errors, keep pressed the ‘ ’ INFO button, in OFF mode position, for 5 The errors number will appear in chronological order (-1- = first fault… -5- = last fault). Use ‘ ’...
  • Page 74 Burner Electrode & Ionization Specifications Pressures in excess of 14”WC may damage the internal components of this boiler. Pensotti REQUIRES replacment of the gas valve if it is subjected to pressures in excess of 14”WC. Faliure to comply could cause dangerous operating...
  • Page 75: Function Codes

    MAINTENANCE INSTRUCTIONS 6.9 Function codes Code Function Description Pressing ‘ ’ button for 7 seconds the Flue test function is enabled. Pressing Flue test function the boiler Off button the function is disabled. enabled (Chimney- The Flue test function operates the boiler at the maximum heating pressure Sweeper) for 15 minutes without any modulation.
  • Page 76: Parts List - Exploded Drawings

    MAINTENANCE INSTRUCTIONS 6.10 Exploded Drawings...
  • Page 77 MAINTENANCE INSTRUCTIONS...
  • Page 78 MAINTENANCE INSTRUCTIONS...
  • Page 79 MAINTENANCE INSTRUCTIONS...
  • Page 80: Warraty Information

    LIMITATIONS OF WARRANTY: This is the only warranty given by Pensotti Boilers. No one is authorized to make any other warranties on Pensotti LLC behalf. This warranty is in lieu of all other warranties, expressed or implied, including but not limited to any implied warranties of fitness for a particular purpose and merchantability. Pensotti LLC expressly disclaims and excludes any liability for consequential, incidental, indirect or punitive damages for breach of any express or implied warranty.
  • Page 81 Pensotti LLC 34 Coffin Ave Brewer, ME 04412 P. 207-942-3636 F. 207-942-3737 www.pensottiboiler.com...