LCD DISPLAY ICONS' KEY
1.
PARAMETER NUMBER INFORMATION
2.
PARAMETERS PROGRAMMING MODE ON
3.
SOLAR PCB CONNECTION INFORMATION /
SOLAR PANEL TEMPERATURE DISPLAY (d6)
4.
SOLAR PUMP ON
5.
SOLAR STORAGE CYLINDER LOW LEVEL
TEMPERATURE VISUALIZATION (d7) /
STORAGE CYLINDER HIGH LEVEL
TEMPERATURE VISUALIZATION (d8)
6.
OUTDOOR TEMPERATURE SENSOR
CONNECTED
7.
TEMPERATURE / SET POINT / PARAMETER
VALUE INFORMATION
8.
OPEN THERM COMPONENTS
COMMUNICATION CONNECTED (REMOTE
CONTROL / ZONE MANAGEMENT CONTROL
BOX)
9.
WATER LOW PRESSURE INFORMATION
10. (*) FLAME PRESENCE ON (3 POWER STEPS)
11. D.H.W. MODE ENABLED
12. RESETTABLE ERROR DISPLAY
13. OFF MODE
14. NOT RESETTABLE ERROR DISPLAY
15. HEATING MODE ENABLED
10 (*) - During the boiler operation the display can show 3
different power levels according to the flame modulation
of the boiler. (See flame icon/power % images)
2.8

INFO Menu display

Press the '
' INFO Button to display the boiler data. Once pressed, the parameter number will appear on the left
side of the display and the associated parameter value will appear on the centre of the display. Use '
buttons of
Heating Temperature setting to scroll the list of available data.
Press the '
' INFO button to exit the display mode.
The list of available display data is the following:
Parameter
Icon
d00
d01
d02
d03
d04
d05
d06
d07
d08
d09
INSTALLATION INSTRUCTIONS
DHW sensor temperature
Outdoor sensor temperature (only with sensor temperature connected)
Fan speed
Low temperature circuit sensor (only with Zone PCB connected)
Heating return sensor temperature (only with modulating pump connected)
Solar panel sensor temperature (only with Solar PCB connected)
Solar storage cylinder temperature (low level) (only with Solar PCB connected)
Solar storage cylinder temperature (high level) (only with Solar PCB connected)
Solar panel sensor temperature 2 [ only with Solar PCB connected ] (SCS2)
Extra Solar storage cylinder temperature [ only with Solar PCB connected ] (SBS3)
4
3
2
1
15
14
< 33%
Description
5
6
7
13
12
>33%<66%
>66%<100%
' and '
8
9
10
11
'
16