To Configure Analogue Lines; To Programme Loop Calling On Analogue System Lines; Programming Guarded Clear - BT Versatility V16 Owner's Manual

Versatility system
Hide thumbs Also See for Versatility V16:
Table of Contents

Advertisement

To configure Analogue Lines

There are various options to configure the Analogue Line interfaces on your system. It is
recommended that these settings should only be altered from the original settings if
there has been a change in the network connection.
• From the Programming Extension, press the Programme Key
• Press the Scroll Down Key
• Select 'System programming'.
• Enter the System Programming Password and select 'Lines'.
• Press the Scroll Down Key
• Select 'PSTN' programming'.
• Select the desired option as detailed in the table below. The options are either
explained in the following pages or in the referenced pages.
Press the Hands-free Key to finish programming.
PSTN Programming Option
Loop calling
Guarded Clear
CDS Detection
Tone Dialling
Disable Dial tone detect

To programme Loop Calling on Analogue system Lines

All Analogue lines are programmed by default to use standard Analogue signalling.
You can programme your Analogue lines to use Loop Calling if required. The benefit of
having lines programmed for Loop Calling is that the line will not be disconnected by
the switch if a digit is not dialled.
• From the Programming Extension, press the Programme Key
• Press the Scroll Down Key
• Select 'System programming'.
• Enter the System Programming Password and select 'Lines'.
• Press the Scroll Down Key
• Select 'PSTN programming'.
• Select 'Loop calling'.
• A menu showing the Analogue lines will be presented. The lines using Loop Calling
are indicated by a _. Those using the standard signalling are indicated by a ◊. Select
the lines as required.
Press the Hands-free Key to finish programming.

Programming Guarded Clear

On standard Analogue lines on the BT Versatility the Guarded Clear option is
programmed. The system can then detect when callers go on hook and automatically
clear down lines. This supervision on lines enables the trunk to trunk services to be
available on the lines.
If guarded clear is turned off then the trunk to trunk services are not available as the
system cannot detect when calls have been completed.
until 'System programming' is displayed.
until 'PSTN Programming' is displayed.
Default setting
Loop calling not set
Guarded clear is enabled
CDS not set
Tone dialling is enabled
Off
until 'System programming' is displayed.
until 'PSTN' programming' is displayed.
.
Alternate setting
Loop calling set
Guarded Clear not enabled
(No Tk to Tk)
CDS set
Tone dialling is not enabled
On
.
BT Versatility
Owners Manual
Call Logging
79

Advertisement

Table of Contents
loading

This manual is also suitable for:

Versatility v8

Table of Contents