7.2.5

Class 0x28 (Motor data object)

 Class 0x28 Instance 1
[Attribute]
Class 0x28 Instance 1
Attribute
Access
Name
ID
3
Get
Motor Type
Rated Motor
6
Get/Set
Current (Pr. 9)
Rated Voltage
7
Get/Set
(Pr.19)
[Service]
Service code
0x0E
Get Attribute Single
0x10
Set Attribute Single
Data
No. of
Range
type
data bytes
USINT
1
3, 7
0 to
UINT
2
0xFFFF
0 to
UINT
2
0xFFFF
Definition
Definition
3: PM motor
7: Squirrel-cage induction motor
[GET]
Return the Pr. 9 setting in 0.1 A increments. (For the FR-
A820-03160(55K) or lower, FR-A840-01800(55K) or lower,
FR-F820-02330(55K) or lower, FR-F840-01160(55K) or lower
round the value to one decimal place.)
[SET]
Write the value to Pr. 9 in 0.1 A increments.
[GET]
• When Pr. 19 = "9999" or "8888", return "200" for the 200 V
class and "400" for the 400 V class.
• When Pr. 19 = "0 to 1000", return the Pr. 19 setting. (decimal
places are rounded)
[SET]
Write the setting value ("0 to 1000, 65535 (9999), or 65520
(8888)") to Pr.19.