Vega VEGAPULS 63 Operating Instructions Manual page 33

Radar sensor for continuous level measurement of liquids, 4...20 ma/hart two-wire
Hide thumbs Also See for VEGAPULS 63:
Table of Contents

Advertisement

VEGAPULS 63 • 4 ... 20 mA/HART two-wire
The following features form the basis of the applications:
Storage tank:
Setup: large-volumed, upright cylindrical, spherical
Product speed: slow filling and emptying
Process/measurement conditions:
– Condensation
– Smooth product surface
– Max. requirement to the measurement accuracy
Storage tanke with product circulation:
Setup: large-volumed, upright cylindrical, spherical
Product speed: slow filling and emptying
Vessel: small laterally mounted or large top mounted stirrer
Process/measurement conditions:
– Relatively smooth product surface
– Max. requirement to the measurement accuracy
– Condensation
– Slight foam generation
– Overfilling possible
Storage tank on ships (Cargo Tank):
Product speed: slow filling and emptying
Vessel:
– Installations in the bottom section (bracers, heating spirals)
– High sockets 200 ... 500 mm, also with large diameters
Process/measurement conditions:
– Condensation, buildup by movement
– Max. requirement on measurement accuracy from 95 %
Stirrer vessel (reactor):
Setup: all vessel sizes possible
Product speed:
– Fast to slow filling possible
– Vessel is very often filled and emptied
Vessel:
– Socket available
– Large agitator blades of metal
– Vortex breakers, heating spirals
Process/measurement conditions:
– Condensation, buildup by movement
– Strong spout generation
– Very agitated surface, foam generation
Dosing vessel:
Setup: all vessel sizes possible
Product speed:
– Fast filling and emptying
6 Set up with the display and adjustment module