Oracle MiniCluster S7-2 Service Manual page 23

Table of Contents

Advertisement

Open the drive lever on the replacement drive and slide the replacement drive as far into the
drive slot as possible and then close the lever to lock it into place. Check that the drive is locked
in place and flush with the other drives.
2.
Log into the mcmu CLI as a primary admin such as mcinstall.
See
Step 1a
and
Step 1b
those instructions.
3.
Identify the full disk name of the replaced drive.
You can use a command such as diskinfo.
In this example, HDD8 was replaced, and diskinfo shows that the full drive name for HDD8 is
c0t5000CCA0536CA710d0.
Also note that the storage array drives are identified by a JBODARRAY string.
% diskinfo
D:devchassis-path
---------------------------------- ---------------------
/dev/chassis/SYS/HDD0/disk
/dev/chassis/SYS/HDD1/disk
/dev/chassis/SYS/HDD2/disk
/dev/chassis/SYS/HDD3/disk
/dev/chassis/SYS/HDD4/disk
/dev/chassis/SYS/HDD5/disk
/dev/chassis/SYS/HDD6
/dev/chassis/SYS/HDD7
/dev/chassis/SYS/MB/EUSB-DISK/disk c1t0d0
in
"Remove a Storage Array HDD or SSD (CRU)" on page 19
c:occupant-compdev
c0t5000CCA02D1EE2A8d0
c0t5000CCA02D1E7AACd0
c0t5000CCA02D1EDCECd0
c0t5000CCA02D1ED360d0
c0t5000CCA02D1EE6D8d0
c0t5000CCA02D1EE6CCd0
-
-
Servicing CRUs That Do Not Require System Power Off
Install a Storage Array HDD or SSD (CRU)
for
23

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MiniCluster S7-2 and is the answer not in the manual?

Table of Contents