AUTODOME IP 4000 HD
9.4
Installing the Surface Mount Adapter
1.
2.
3.
4.
Figure 9.2: Mount with 4 screws
5.
6.
Figure 9.3: Attach conduit, route cables
7.
Bosch Security Systems
Determine a secure location for mounting the surface mount adapter (NEZ-A4-SMB) and
the camera.
Use the adapter as a template to mark the installation location for four (4) M4 or #10 pan
head screws (with a minimum length of 10 mm (0.39 in.)) (user-supplied).
Drill the four (4) holes in the installation location.
Attach the surface mount adapter to the surface using the four screws.
Attach conduit to the side of the adapter from which you removed the plug (the side from
which the external cables are to be routed).
Route the external cables (24 VAC, CAT 5/CAT6, alarm and/or audio as needed) through
the conduit and into the surface mount adapter.
Attach the mounting plate (supplied with the camera) to the surface mount adapter with
the three (3) M4 – .7 x 8 Phillips pan head machine screws (supplied with the surface
mount adapter).
Installing a Surface Mount and Camera | en
RJ45
24 VAC
Installation Manual
x4 T5
Earth
25
2015.11 | 1.1 |