DISPENSER INSTALLATION

1. Order the proper cuber/dispenser adaptor kit. This package include gasket material, a hold-down
bracket, and bin stat kit (contact service provider for more information).
2. RTV applications (See Figure 3). If the ice bin is full, new ice will not be able to drop. Instead it
blocks the evaporator curtain open and no additional ice is made. This new ice may start to melt and
the resulting liquid can leak out of the joint between the ice maker and bin. To prevent this problem,
seal the joint with food grade silicon sealant.
FIGURE 3
3. Install Bin stat, Part No. 631500074 (See Bin Stat Kit Instructions).
Figure 4 is an example of a typical electrical and plumbing connection.
Bin Drain
Tube
AIR-COOLED MODELS
FIGURE 4
* An air gap of at least twice the diameter of the water supply inlet plus a minimum of 1" (25 mm) must
exist between the floor drain and drain tube.
NOTE: Leave all panels on the cuber until it is in place on the bin.
October 17, 2005
Electrical Service Line
Manual Disconnect
Switch
Shut-Off Valve
Water Filter
STRAIN RELIEF
MUST BE USED
Dump
Valve
Drain
Tube
*Air Gap 4"
"minimum"
Floor Drain
Bin Drain
Tube
WATER-COOLED MODELS
7
Electrical Service Line
Manual Disconnect Switch
Shut-Off Valve
Water Filter
Shut-Off Valve
Condenser Water Inlet
Strain Relief
must be used
Dump Valve
Drain Tube
Condenser Water
Drain Tube
*Air Gap 4"
"minimum"
Floor Drain
TP00952