Safety (New Software); Safety Features; Flashing Code For Self Diagnostics; Flashing Code For Self Diagnostics (1400'S And 1800'S) - Cornelius XAC 1444 Service Training Manual

Xtreme ice xac series; xwc series; xrc series;
Hide thumbs Also See for XAC 1444:
Table of Contents

Advertisement

Xtreme Ice Training Manual
NOTE: After S/N 63K0344BC050 for self–contained units and S/N 63M0351BC056 for remote units.

SAFETY FEATURES

1. Failed Freeze Shutdown
2. Failed Harvest Shutdown
3. Bin Full Delay
4. Low Condenser Temperature Warning
5. High Condenser Temperature Warning and Shutdown
6. Open Condenser Thermistor Shutdown
7. Inlet Warning
8. Failed Water System Shutdown
9. Failed Water Temperature Shutdown
10. Open Water Thermistor Shutdown
FLASHING CODE FOR SELF DIAGNOSTICS (300'S, 500'S, 600'S,
800'S, 1000'S, AND 1200'S)
NOTE: After S/N 63K0344BC050 for self–contained units and S/N 63M0351BC056 for remote units.
Warning LED
1
High Condenser Temperature Warning
4
Low Condenser Temperature Warning
5
Water Inlet Warning

FLASHING CODE FOR SELF DIAGNOSTICS (1400'S AND 1800'S)

NOTE: After S/N 63K0344BC050 for self–contained units and S/N 63M0351BC056 for remote units.
Warning LED
1
High Condenser Temperature Warning
4
Low Condenser Temperature Warning
5
Water Inlet Warning
October 17, 2005

SAFETY (NEW SOFTWARE)

Error LED
1
High Condenser Temp. Shutdown
2
Failed Freeze Time Out Shutdown
3
Failed Harvest Shutdown
5
Failed Water System Shutdown
6
End of Clean Cycle Shutdown
8
Open Condenser Thermistor Shutdown
Error LED
1
High Condenser Temp. Shutdown
2
Failed Freeze Time Out Shutdown
3
Failed Harvest Shutdown
4
Failed Water Temperature Shutdown
5
Failed Water System Shutdown
6
End of Clean Cycle Shutdown
7
Open Water Thermistor Shutdown
8
Open Condenser Thermistor Shutdown
25