Advertisement

DISPENSER INSTALLATION

The proper cuber/dispenser installation package should be ordered. This package will include gasket material
and hold-down bracket.

PLUMBING CONNECTIONS

1. All plumbing lines and connections must conform to local and national plumbing codes.
2. Line shut-off valves must be located in supply water lines for cuber and condenser if product is water-
cooled. Water supply to water-cooled condenser must include a stand-pipe to prevent "water hammer".
3. Should your local water supply quality require the installation of a water filter system, consult your local dis-
tributor or dealer for proper size required.
4. Water supply pressure must not be lower than 20 PSI (1.37 BAR), nor should it exceed 120 PSI (8.16
BAR).
IMPORTANT: Water filters larger then 5 microns do not give proper protection. Water pressures above
80 PSI (5.44 BAR) will destroy the filter.
NOTE:
Bin and cuber drain lines must never be connected together and must be vented.
166240001
BIN DRAIN TUBE
xii
ELECTRICAL SERVICE LINE
MANUAL DISCONNECT SWITCH
SHUT-OFF VALVE
WATER FILTER
STRAIN RELIEF
DUMP VALVE
DRAIN TUBE
AEROQUIP VALVE FITTING
FLOOR DRAIN