NOTE: The purge drain fitting is plastic: DO NOT apply heat to purge drain area; DO NOT over-tighten drain
connection.
All drain lines must be installed per local codes. The purge drain should be a minimum of 3/4 inch O.D. tubing. The
condenser drain on water cooled units should be 1/2 inch O.D. minimum. The drain line fittings on Cornelius bins are
3/4 FPT. The bin drain should be a minimum of 3/4 inch O.D. Cold water drains should be insulated to prevent con-
densation from forming.
C
R
LEARANCE
EQUIREMENTS
Self-contained air cooled ice machines must have a minimum of 6 inches (15cm) of clearance at the rear, top, and
sides for proper air circulation and adequate space for serviceability.
Self-contained air-cooled ice machines exhaust air out of the top and right side. There are two alternative air exhaust
options. Option A (top exhaust bias): minimum of 6 inches (15cm) of clearance at the rear and top of the ice machine
for proper function at maximum operating conditions. Option B (side exhaust bias): minimum of 6 inches (15cm) of
clearance at the rear and right side of the ice machine with a minimum of 3 inches (7.5cm) of clearance at the top for
proper function at maximum operating conditions.
Appropriate space should be allowed for proper serviceability of the machine. Excess time to gain access for service-
ability is not covered under warranty.
S
TACKING
Cornelius does not endorse stacking ice machines.
D
A
ISPENSER
PPLICATION
A thermostatic bin control kit should be installed if the ice machine is placed on a dispenser. A bin top may or may not
be required and should be secured to the dispenser.
E
S
LECTRICAL
PECIFICATIONS
Refer to the serial plate at the rear of the ice machine to make sure proper voltage and circuit breaker size have been
supplied. Make sure the machine is on a dedicated circuit. European installations require that the electrical supply
fixed wiring must be provided with a disconnect means having a separation of at least 3mm in all poles. The ice
machines are provided without an electrical cord set and are designed and agency approved to be permanently con-
nected.
NOTE: Units are not approved for GFI outlets.
!
CAUTION
Electrical connection must be made or a cord installed by a qualified electrician or there is danger of an electrical
fire.
A
DJUSTMENTS
Level the machine within 1/8 inch in all directions. Check the water in the Water Sump for proper level.
Check the ice bridge for proper thickness. Check the Water Regulating Valve adjustment if water cooled.
Secure the machine on top of the bin or dispenser. Attach the ice machine to the bin with the mounting straps pro-
vided with the bin or dispenser. Insure that the back of the ice machine is flush with the back of the bin. Proper func-
tioning of the Bin Door requires the door, when it is opened, to be in a stable position.
If the ice machine is too far forward on the bin, the opened door may not be stable, resulting in an unexpected closing
of the bin door. If the ice machine is to be mounted on a bin or dispenser other than a Cornelius, refer to the manufac-
turers instructions for machine mounting. Cornelius will not be responsible for damage or injury that results from unex-
pected closing of the bin door as a result of the ice machine being too far forward on the bin.
© 2018, Cornelius Inc.
Installation Guide and Owner's Manual
- 5 -
Publication Number: 548000033