Xtreme Ice Training Manual
NOTE: Prior to S/N 63K0344BC050 for self–contained units and S/N 63M0351BC056 for remote
units.
SAFETY FEATURES
1. Water Fill Time Out
2. Maximum Freeze Time Out
3. Harvest Time Out
4. Bin Full Delay
5. Low Condenser Temperature Delay
6. High Condenser Temperature
7. Open Condenser Thermistor
8. Failed Water Temperature
9. Open Water Thermistor
FLASHING CODE FOR SELF DIAGNOSTICS (300'S, 500'S, 600'S,
800'S, 1000'S, AND 1200'S)
NOTE: Prior to S/N 63K0344BC050 for self–contained units and S/N 63M0351BC056 for remote
units.
Delay LED "Yellow"
1
High Condenser Temperature Delay
2
Water Fill Time Out Delay
3
Failed Harvest Delay
4
Maximum Freeze Time Out Delay
6
Low Condenser Temperature Delay
FLASHING CODE FOR SELF DIAGNOSTICS (1400'S AND 1800'S)
NOTE: Prior to S/N 63K0344BC050 for self–contained units and S/N 63M0351BC056 for remote
units.
1
High Condenser Temperature Delay
2
Water Fill Time Out Delay
3
Failed Harvest Delay
4
Maximum Freeze Time Out Delay
5
Failed Water Temperature Delay
6
Low Condenser Temperature Delay
October 17, 2005
SAFETY (OLD SOFTWARE)
Error LED "Red"
1
High Condenser Temp. Shut Down
2
Water Fill Time Out Shut Down
3
Failed Harvest Shut Down
4
Maximum Freeze Time Out Shut Down
6
Low Condenser Temperature Shut Down
7
Open Thermistor Shut Down
8
End of Clean Cycle Shut Down
1
High Condenser Temp. Error
2
Water Fill Time Out Error
3
Failed Harvest Error
4
Maximum Freeze Time Out Error
5
Failed Water Temperature Error
6
Low Condenser Temperature Error
7
Open Condenser Thermistor Error
8
End of Clean Cycle Error
9
Open Water Thermistor Error
21
TP00952