Download Print this page
sauter SW 1000 User Manual

sauter SW 1000 User Manual

Sound level meter with octave-band analyzer
Hide thumbs Also See for SW 1000:

Advertisement

Quick Links

User's manual (short )
Sound level meter with octave-band
analyzer
SW 1000/SW 2000
devices belong to the new genera-
tion of sound level meters with octave-band analyzer.
The devices are equipped in the processor of ARM
architecture with FPU arithmetic coprocessor and
instead of fixed-point calculations they perform float-
ing-point calculations what definitely increases their
accuracy and stability. Its own noise is reduced by the
newly-designed analogue input module.
Main features
Class 1
(SW
1000) and class 2
It meets the requirements of GB/T 3785.1-2010,
IEC 60651:1979, IEC 60804:2000, IEC 61672-1:2013,
ANSI S1.4-1983, ANSI S1.43-1997 standards
1/1-octave-band analyser conforms to
GB/T 3241-2010, IEC 61260-1:2014, ANSI S1.11-2004
standards.
Frequency band:
SW 1000: 31.5 Hz~16 kHz
SW 2000: 31.5 Hz~8 kHz
Added microphone:
SW 1000: MPA231T, class 1.50 mV/Pa,
10 Hz~20 kHz
SW 2000: MPA309T, class 2.40 mV/Pa,
20 Hz~12.5 kHz
Own noise:
1000 (sound): 18 dB(A), 23 dB(C), 31 dB(Z)
1000 (electric): 11 dB(A), 16 dB(C), 21 dB(Z)
2000
(sound): 20 dB(A), 26 dB(C), 31 dB(Z)
2000
(electric): 14 dB(A), 19 dB(C), 24 dB(Z)
Upper limit value:
1000: 134 dB(A), increased with the use of the mi-
crophone of smaller sensitivity
2000: 136 dB(A), increased with the use of the mi-
crophone of smaller sensitivity
SW 1000_SW 2000-KA-e-1710
Sauter GmbH
Ziegelei 1 Telefon: +49-[0]7433-9933-0
Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com
D-72336 Balingen
Email: info@kern-sohn.com
SW 1000 / SW 2000
(SW
2000)
Frequency characteristics:
1000: 10 Hz~20 kHz
2000: 20 Hz~12.5 kHz
Linearity range:
1000: 20 dB(A)~134 dB(A)
2000: 25 dB(A)~136 dB(A)
Dynamic range: 1000: 123 dB, 2000: 122 dB
Maximum range of carrier wave:
1000: 45 dB(A)~137 dB(A)
2000: 47 dB(A)~139 dB(A)
A/B/C/Z frequency correction. F/S/I time constant and
determination of the peak value
One range covering the whole dynamic range
L
, L
, L
, L
XY(SPL)
Xeq
XYSD
L
. where: X means frequency correction: A, B, C, Z;
XN
Y means time constant: F, S, I; N means statistical
measure: 1~99
Integration time: infinite, 1 s~24 h, number of repeti-
tions: Inf, 1~9999
Log cycles below 1 s: 0.1 s; 0.2 s; 0.5 s
3 parallel profile calculations with various frequency or
time constant. 14 measurements defined by the user
Possibility of importing/exporting 5 configuration
patterns with the use of SD card
Automatic turning on with external electric power
supply, easy integration
MicroSD (TF) memory card with the capacity of 4 GB,
USB drive mode operation
GRS-232 socket may be used as a control socket or in
order to connect the thermal printer
Output: alternate current voltage (maximum 5 V
direct current voltage (10 mV/dB)
Real time clock RTC with the buffer battery, factory
calibrated, deviation within 30 days amounting to 30 s
maximum (< 10 pm, RT)
Internal GPS module (option), GPS time operation
, L
, L
, L
, L
XSEL
XE
XYmax
XYmin
sk
1
,
XPeak
),

Advertisement

loading

Summary of Contents for sauter SW 1000

  • Page 1 MicroSD (TF) memory card with the capacity of 4 GB,  Added microphone: USB drive mode operation  SW 1000: MPA231T, class 1.50 mV/Pa,  GRS-232 socket may be used as a control socket or in 10 Hz~20 kHz order to connect the thermal printer ...
  • Page 2: External View

    Sauter GmbH Ziegelei 1 Telefon: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com D-72336 Balingen Email: info@kern-sohn.com SW 1000 / SW 2000 Packaging Interface PWR: Direct current power supply socket: 7 V~14 V. ☆NOTE: With the working voltage above 14 V, the device is damaged! MiniUSB: USB disc mode or modem mode.
  • Page 3: Button Field

    Sauter GmbH Ziegelei 1 Telefon: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com D-72336 Balingen Email: info@kern-sohn.com SW 1000 / SW 2000 <▲>: Up arrow button, while selecting the option or Button field changing the value. Indicator <▼>: Down arrow button, while selecting the option or changing the value.
  • Page 4: Battery Replacement

    Ziegelei 1 Telefon: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com D-72336 Balingen Email: info@kern-sohn.com SW 1000 / SW 2000 MicroSD card status. It is dis- Battery replacement played while data are being In the sound level meter there are 4 alkali batteries saved.
  • Page 5: Additional Information

    Sauter GmbH Ziegelei 1 Telefon: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com D-72336 Balingen Email: info@kern-sohn.com SW 1000 / SW 2000 time (Czas całkowania): (Próg alarmu): Time for calculating integration data, for example LEQ, When the result exceeds the threshold value, LED MAX, MIN etc.

This manual is also suitable for:

Sw 2000