Thermo-hygrometer

Advertisement

Quick Links

THERMO-HYGROMETER
Thank you very much for buying a SAUTER Thermo-
Hygrometer. We hope that you are pleased with your high
quality instrument and its functional range.
These kinds of instruments are widely used in laboratory,
warehouse, air conditioning systems, quality control etc.
Although this is a complex and delicate instrument, its
ruggedness will allow many years of use if you will care for
an appropriate operation and maintenance.
Please read the instruction manual carefully and always
keep it within reach.
If there are any queries, wishes or helpful suggestions, do
not hesitate to call our service number.
Table of contents
1. Functions
2. Operation
3. General Specifications
4. Description of parts
5. CE Declaration of Conformity
1. Functions
* Large dual LCD Display
* Humidity and temperature measurement
* Humidity and temperature max. / min. measurement
* Data HOLD-Function: to freeze the currently measured
value
*
-selection key
* Low battery indication
* Auto-Power-Off
* LCD backlight
* K-Type wire sensor for temperature measurement
2. Operation
a) The battery cover has to be opened and a 9V battery
has to be installed correctly. Then the ON/OFF button has
to be pressed to turn the instrument on for measuring.
SX_50C-BA-e-1110
Sauter GmbH
Tieringerstr. 11-15
D-72336 Balingen
E-Mail: info@sauter.eu
Instruction Manual
SX 50C
b)
units between Celsius and Fahrenheit for temperature
measurement.
c) Temperature MAX/ MIN- Function: Storage of max./
min. values. If the button T MAX/MIN is being pressed for
the first time, the max. temperature value will be shown.
If the button is being pressed a second time, the min.
temperature value of a measuring process will be shown
and it will be saved.
d) Humidity MAX/MIN- Function: If the button RH
MAX/MIN is being pressed for the first time, the max.
humidity value will be shown. If the button is being pressed
a second time, the min. humidity value of a measuring
process will be shown and it will be saved.
e) HOLD- Function: In normal measurement mode, the
actual measured value can be frozen at any time by
pressing the
pressed again, one returns to normal measurement mode.
The same procedure is valid for humidity measurement:
here the button RH HOLD has to be pressed.
f) K-Typ temperature measurement with wire sensor:
The instrument has to be connected with a wire sensor.
Soon after, the K-Type temperature measurement mode
will appear on the display. If the instrument is disconnected
from the wire sensor, it will return to normal measurement
mode.
g) LCD Display with backlight: If the button
longer than 2 seconds, the backlight function will be
activated. If it is pressed again, backlight is turned off.
h) ON/OFF button: There will be an automatic shut-down
after 10 minutes, as long as no button is being pressed or
any operation is being done. The instrument can also be
turned on or off manually at any time by pressing this
button.
3. General Specifications
Temperature Range: -10°C up to +50°C
K-Type wire sensor Temperature Range:
Relative Humidity Range: 5,0% up to 98% RH
Accuracy Temperature: ± 2°C
K-TYPE: ± 4°C
Accuracy Relative Humidity: 3,5% RH
Resolution Temperature: 1°C
Resolution Relative Humidity: 0,1% RH
Tel: +49-[0]7433- 9976-174
Fax: +49-[0]7433-9976-285
Internet: www. sauter.eu
-selection key: This key has to be pressed to select
T HOLD-button. If this button is being
-20° up to 1000°C
is pressed
1

Advertisement

loading

Summary of Contents for sauter SX 50C

  • Page 1 Thank you very much for buying a SAUTER Thermo- e) HOLD- Function: In normal measurement mode, the Hygrometer. We hope that you are pleased with your high actual measured value can be frozen at any time by quality instrument and its functional range.
  • Page 2 Sauter GmbH Tieringerstr. 11-15 Tel: +49-[0]7433- 9976-174 D-72336 Balingen Fax: +49-[0]7433-9976-285 E-Mail: info@sauter.eu Internet: www. sauter.eu Instruction Manual SX 50C Sampling rate: 2.5 x times per second Power supply: 1 x 9V battery 5. CE Declaration of Conformity Operating conditions: -10°C up to +50°C...