sauter  TE SERIES Instruction Manual

sauter TE SERIES Instruction Manual

Digital coating thickness gauge

Advertisement

Instruction Manual
Digital Coating Thickness Gauge
SAUTER TE
Version 1.2
08/2018
GB
Sauter GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@sauter.eu
Tel: +49-[0]7433- 9933-199
Fax: +49-[0]7433-9933-149
Internet: www.sauter.eu
PROFESSIONAL MEASURING
TE-BA-e-1812

Advertisement

Table of Contents
loading

Summary of Contents for sauter SAUTER TE SERIES

  • Page 1 Sauter GmbH Ziegelei 1 Tel: +49-[0]7433- 9933-199 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-Mail: info@sauter.eu Internet: www.sauter.eu Instruction Manual Digital Coating Thickness Gauge SAUTER TE Version 1.2 08/2018 PROFESSIONAL MEASURING TE-BA-e-1812...
  • Page 2: Table Of Contents

    Instruction Manual Digital Coating Thickness Gauge Thank you for buying the digital thickness gauge by SAUTER. We hope you will be happy with the high quality of this measuring instrument and its numerous functionali- ties. Should you have any questions, requests and suggestions, do not hesitate to contact us.
  • Page 3: Functions

    This thickness gauge is small, lightweight and handy. Although its components are complex and advanced, it is convenient and easy to use. Its durability allows to use it for many years, provided all the guidelines in this User Manual are complied with strictly. This is why you should always have it within arm's reach! Please note: Before first use of the new measuring instrument it is recom- mended to adjust it as described in chapter 5.
  • Page 4: Technical Specifications

    2 Technical Specifications Display: LCD, 4-digit, digit height 10 mm, backlit Measurement range: 0–1250 µm/0–50 mil (standard) (other measurement range can be set) Resolution: 0.1 µm (from 0 to 99.9 µm) 1 µm (above 100 µm) Uncertainty of measurement: — Standard: 3% of the measurement value or Min value ±2.5 µm For the tolerance ±100 µm of the typical measurement range, if the two-point calibra- tion has also been carried out in that tolerance range.
  • Page 5: Operating Panel Description

    3 Operating Panel Description 3-10 here: TE 1250-0.1FN model Measuring probe Display "ZERO" button "Plus" button "Minus" button "ON/OFF" (multipurpose) button "µm/mil" switch button (keyboard shortcut) Battery compartment/cover — back Port of RS-232C interfaces 3-10 "S/C" (single/continuous) measurement mode button 4 Measurement Procedure 4.1 Insert the F- or N-type measuring probe, depending on the measured object.
  • Page 6: Adjustment

    4.5 If there are any measurement inaccuracies, it is recommended to adjust the measurement instrument as described in chapter 5 before you start measuring. 4.6 The device can be switched off by pressing "ON/OFF". Otherwise, it will switch off automatically 50 s after a button was last pressed. 4.7 The measurement result can be displayed in µm or mil: —...
  • Page 7: Battery Replacement

    6 Battery replacement 6.1 Batteries should be replaced once the battery symbol is displayed. 6.2 Slide the battery compartment cover 3-8 out of the measurement instrument and remove the batteries. 6.3 Insert batteries (4 × 1.5 V, AAA/UM-4), paying attention to their polarity. 6.4 If the device is unused for an extended period of time, remove the batteries.
  • Page 8: 11 Comments

    — deteriorated measurement accuracy due to drastic changes in the operating envi- ronment of the measurement instrument; — following replacement of the measuring probe. Factory settings include both settings for "Fe" (F) and "NFe" (N) materials. It can be set for one or both of them. The procedure is described below: It is different for "Fe"...
  • Page 9: Te-Ba-E

    And the other way round, LN value should be decreased when the readout value in the lower range is correct (e.g. 51 µm), and in the upper it is too low (e.g. 432 µm). C. The processes in A and B should be repeated until the readout for every adjust- ment film is satisfactory in terms of its accuracy.

This manual is also suitable for:

Sauter te 1250-0.1 nSauter te 1250-0.1 fTe 1250-0.1 fn