DISPLAY MESSAGES

Cold Start!
Overload! #nn
Power Outage!
Fuse Open!
38
1. Someone performed an Erase
Program sequence.
2. Battery failure.
1. Solenoid failure at valve nn.
2. Programming error caused too many
valves to come on (more than 3
Amps).
3. Wiring to valve is damaged.
1. Power to the field controller has
been interrupted.
1. Fuse has blown.
GENESIS OPERATIONS MANUAL
1. Press CLEAR to remove message
from display.
2. Return the facepack to the factory
or the nearest authorized Service
Center.
1. Replace solenoid at valve nn.
2. Review all Programs and Starts
for overlaps.
3. Perform ground fault check on
valve wiring and repair or replace
if necessary.
1. Press CLEAR to remove message
from display.
1. Check all valve wiring and
solenoids for short to ground and
replace fuse. (Message will
disappear once a good fuse is put
into place.)