Safety Precautions
Inspect the electrical cord
WARNING
and plug for damage prior
to plugging the unit in.
If service is necessary,
CAUTION
r e p a i r w o r k m u s t b e
performed by a Perlick authorized servicer.
Work done by unqualified individuals could
83 11/16"
potentially be dangerous and will void the
warranty.
If unit has been laid on its
CAUTION
back or sides, place unit
upright and allow minimum of 24 hours before
connecting power. Failure to follow this
procedure may damage the compressor and
void the warranty.
D o n o t u s e o r s t o r e
DANGER
flammable liquids (ie;
14 1/8"
gasoline) or vapors near the appliance.
Perlick columns are top
DANGER
heavy. It is important that it
OVERLAY TEMPLATE
is secured at all times with the door closed
DIMENSIONAL LIMIT
until installed. Install as directed using anti-tip
brackets provided to prevent tipping.
Take special care when
DANGER
moving to prevent injury.
Electrical
DANGER
S e r i o u s e l e c t r o c u t i o n
hazard. Electrical grounding is required. This
appliance is equipped with a 3-prong
(grounding) polarized plug for your protection
against possible shock hazards. Failure to
comply with these electrical guidelines may
result in possible death or serious injury, fire
or loss of property.
WARNING
cord to connect the unit to the electrical
source. Do not use a two-prong adapter or
remove the power cord ground prong.
Printed in USA
Wine Column Refrigeration Installation & Operation Manual
PRIOR TO INSTALLATION
13 3/8"
1 4/5"
21.5/8"
Never use an extension
Installation must comply with all applicable
electrical codes. The electrical supply must be
located within the shaded area of the illustration
below. A separate circuit, servicing only this
appliance, is required. A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation. The outlet should
be placed in the hatched area dimensioned below.
Electrical Supply
Service
Power/Cord Type/
Length
10 3/4"
3"
4"
3"
4
24"
115V, 60Hz., Phase 1, 3.3
amps
Dedicated 15 amp circuit
NEMA 5-15P w/5' power cord
5 1/4"
1/2"
ELECTRICAL
OUTLET
LOCATION
84"
Need help?
Do you have a question about the CC24W Series and is the answer not in the manual?
Questions and answers