Peer-To-Peer Mode For 4:1 Pci Riser Modules; Peer-To-Peer Mode For 8:1 Pci Riser Modules; Nvidia Tesla P4 Gpu Support Matrix; Replacing The Failed Amd S9150 Gpu Accelerator - HP ProLiant XL270d Gen9 Maintenance And Service Manual

Accelerator tray
Table of Contents

Advertisement

Peer-to-peer mode for 4:1 PCI riser modules

Number
Slot 1
of GPUs
2
GPU
4
GPU
6
GPU
8
GPU

Peer-to-peer mode for 8:1 PCI riser modules

Number
Slot 1
of GPUs
2
GPU
4
GPU
6
GPU
8
GPU

NVIDIA Tesla P4 GPU support matrix

Number
of GPUs
Slot 1
Baffle
Required
2
GPU
4
GPU
6
GPU
8
GPU

Replacing the failed AMD S9150 GPU accelerator

Procedure
1.
Back up all server data.
2.
Power down the server .
3.
Disconnect all peripheral cables from the server front panel.
4.
Remove the server from the chassis.
5.
Place the server on a sturdy, level surface.
6.
Remove the side panel.
CAUTION:
To prevent improper cooling and thermal damage, do not operate the server unless all bays are
populated with either a component or a blank.
Slot 2
Slot 3
GPU
Blank
GPU
Blank
GPU
GPU
GPU
GPU
Slot 2
Slot 3
GPU
Blank
GPU
GPU
GPU
GPU
GPU
GPU
Left Side
Slot 2
Slot 3
Required
NA
GPU
Blank
GPU
Blank
GPU
GPU
GPU
GPU
Slot 4
Slot 5
Slot 6
Blank
Blank
Blank
Blank
GPU
GPU
GPU
GPU
GPU
GPU
GPU
GPU
Slot 4
Slot 5
Slot 6
Blank
Blank
Blank
GPU
Blank
Blank
GPU
GPU
GPU
GPU
GPU
GPU
Slot 4
Slot 5
Slot 6
NA
Required
Required
Blank
Blank
Blank
Blank
GPU
GPU
GPU
GPU
GPU
GPU
GPU
GPU
Peer-to-peer mode for 4:1 PCI riser modules
Slot 7
Slot 8
Blank
Blank
Blank
Blank
Blank
Blank
GPU
GPU
Slot 7
Slot 8
Blank
Blank
Blank
Blank
Blank
Blank
GPU
GPU
Right Side
Slot 7
Slot 8
NA
NA
Blank
Blank
Blank
Blank
Blank
Blank
GPU
GPU
47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents