To replace the component, reverse the removal procedure.

Enabling the dedicated iLO management module

Procedure
1. During the server startup sequence after installing the module, press F9 in the POST screen.
The System Utilities screen appears.
2. Select System Configuration | iLO 4 Configuration Utility.
The iLO 4 Configuration Utility screen appears.
3. Select Network Options, and then press Enter.
The Network Options screen appears.
4. Set the Network Interface Adapter field to ON, and then press Enter.
5. Press F10 to save your changes.
A message prompt to confirm the iLO settings reset appears.
6. Press Enter to reboot the iLO settings.
7. Press Esc until the main menu is displayed.
8. Select Reboot the System to exit the utility and resume the boot process.
The IP address of the enabled dedicated iLO connector appears on the POST screen on the
subsequent boot-up. Access the Network Options screen again to view this IP address for later
reference.

Heatsink

WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
Enabling the dedicated iLO management module
69