Temperature Control; Determining The Drying Time - Electrolux AWF 1210 Service Manual

Washing machines & washer-dryers with ewm2000 electronic control
Table of Contents

Advertisement

6.1.1

Temperature control

An NTC sensor fitted to the duct is used to control the drying temperature; two safety thermostats (one of
which is a manual-reset type) are fitted to the casing of the heating element.
1. NTC sensor for control of
drying temperature
2. Automatic-reset safety
thermostat
3. Manual-reset safety
thermostat (150ºC)
4. Drying heater
NTC Sensor : resistance at 25°C
Manual-reset safety thermostat
Automatic-reset safety
thermostat
Drying heater power
Fan rate
6.1.2

Determining the drying time:

In automatic cycles, the NTC sensor fitted to the drying condenser is used to control the drying time.
1. NTC temperature sensor
2. Tub-condenser pipe
3. Drying condenser
TSE-P 02.00 EB
"Standard" Version
Normally closed, opens at 150°C
Normally closed, opens at 98°C
700 + 700 W
3
about 55 m
– hour
39/60
"High performance" Version
5000Ω
Normally closed, opens at 110°C
1000+1000 W
about 80 m
3
– hour
599 35 24-30