12.1

Temperature control

The drying temperature is controlled by an NTC sensor positioned on the duct; the heating element casing
features two safety thermostats (one of which is a manual-reset type).
8. Washing heating element
9. PCB - WD
10. Safety thermostat (auto-reset)
11. Safety thermostat (manual reset)
12. Drying heating element
13. Fan motor.
14. Drying control NTC sensor
15. Humidity control NTC sensor
27. Main circuit board
1. Drying temperature control
NTC sensor
2. Auto-reset safety thermostat
3. Manual reset safety
thermostat (150°C)
4. Drying heating element
NTC sensor: heating element at
25°C
Manual reset safety thermostat
Auto-reset safety thermostat
Heating unit
Fan capacity
Calculating the drying time:
In the automatic cycles the NTC sensor mounted on the
drying duct is used to calculate the drying time.
1. NTC temperature sensor
2. Tub-condenser tube
3. Drying condenser
SOI/DT 2010-03 dmm
Power
Power supply
voltage
Resistance
56.5Ω+56.5Ω
59/78
5000Ω
Normally closed,
opens at 150°±5°C
Normally closed
Opens at 110°±3°C
Closes at 94°±5°
920+920 W
230V
240
61.5Ω+61.5Ω
3
approx. 80 m
per hour
599 72 84-41