4.9 "FUCS"

(Fast Unbalance Control System)
The control procedure for unbalanced loads is performed dynamically, before each spin cycle, as follows:
The phase starts with the inversion rotation of the drum at a speed of 55 rpm.
The phase begins at a speed of 55 rpm; the speed can never fall below this threshold, otherwise the
check is repeated.
At intervals of 400 ms, the balance is calculated and compared with predetermined limits. If the value is
less than the lower limit, the speed of the drum is increased by 2 rpm; if the value is higher, the speed of
the drum is reduced by 2 rpm. The reduction in the speed of the drum distributes the washing correctly;
this procedure is repeated until the wash load is completely balanced.
Correct balancing of the wash load is achieved at a speed of 115 rpm, after which the spin cycle begins.
The Unbalancing Control function takes place in four steps: each phase is characterised by a value of
unbalancing threshold and by a time out (max. time)
Step 0: The zero phase has a preset unbalancing threshold; if correct balancing is achieved, the appliance
performs a spin pulse at 470 rpm, preceded by 5 sec at 100 rpm and followed by phase 1;
otherwise, after a maximum of 60 seconds the function passes to step 1.
Step 1: The first phase has a different preset unbalancing threshold; if correct balancing is achieved, the
appliance performs the spin cycle, preceded by 5 sec at 100 rpm. Otherwise, after a maximum of
120 seconds, the function passes to step 2.
Step 2: The second phase is characterised by a different unbalancing threshold: if correct balancing is not
achieved within 60 seconds, the function passes to step 3.
Step 3: The third phase has a preset unbalancing threshold: if correct balancing is achieved within 90
seconds a spin pulse is performed, preceded by 5 sec at 100 rpm and followed by a new step 1;
otherwise, after a maximum of 90 seconds, the function passes to a new step 1.
If the unbalancing value remains excessive at the second attempt during step 3, the spin cycle is
skipped; if the balancing is not correct a reduced spin is performed.
4.9.1

Examples of operation of the unbalancing control function

The following examples refer to an appliance with a final spin speed at 1000 rpm.
Load correctly balanced
Low speed
FUCS phase 0 and pulse
Low speed
FUCS phase 1
Normal spin
TSE-P 02.00 EB
25/60
599 35 24-30