Electrolux AWF 1210 Service Manual page 47

Washing machines & washer-dryers with ewm2000 electronic control
Table of Contents

Advertisement

Alarm
LED
LED
code
L26 -29
L30 - 33
"Sensing" circuit of anti-boiling pressure switch
0
0
1 faulty
0
1
E36
1
1
(input signal to microprocessor always 0V or
1
0
5V)
0
0
"Sensing" circuit of anti-boiling pressure switch
0
1
2 faulty
E37
1
1
(input signal to microprocessor always 0 - 5V)
1
1
0
1
Pressure chamber blocked
0
0
(water level does not vary for at least 30 sec.
E38
1
0
during drum rotation)
1
0
0
0
Door open
1
0
(door delay interlock does not close after 15
E41
0
0
seconds)
0
1
0
0
Problems with door closure
1
0
(door open during cycle for more than 15 sec.
E42
0
1
or door closed after cycle for more than 3 min.)
0
0
0
0
TRIAC which powers the door interlock faulty
1
0
(incongruency between status of door interlock
E43
0
1
"sensing" circuit and status of TRIAC)
0
1
0
0
"Sensing" circuit of door delay interlock faulty
1
1
(input signal to microprocessor always 0V or
E44
0
0
5V)
0
0
0
0
"Sensing" circuit of door delay interlock triac
1
1
faulty (input signal to microprocessor always 0V
E45
0
0
or 5V)
0
1
0
0
TRIAC which powers the motor short-circuited
1
0
(TRIAC short-circuit cut-out activated or motor
E51
0
0
speed more than maximum speed)
1
1
No signal from tachometric generator on motor
0
0
(no signal after maximum time)
1
0
E52
0
1
1
0
SOI/DT 2002-03 eb
Description of fault
User
Effect
code
---
Cycle blocked
Main PCB
with door closed
---
Cycle blocked
Main PCB
with door closed
---
Heating phase
Pressure switch hydraulic circuit; pressure
skipped
switches, motor drive belt broken
E40
Cycle paused
Door open; door delay interlock; wiring; main PCB
E40
Cycle paused
Door delay interlock; wiring; main PCB
E40
Cycle paused
Wiring; main PCB
---
Cycle blocked
Main PCB
---
Cycle blocked
Main PCB
with door closed
---
Cycle blocked
Loss of insulation on motor winding/wiring; main
with door closed
PCB
(after 5 attempts)
---
Cycle blocked
Motor; tachometric generator; wiring; main PCB
with door closed
(after 5 attempts,
the last after 20
sec)
47
Possible causes
599 35 27-25

Advertisement

Table of Contents
loading