7.7 Alarm codes

0:LED off
1: LED flashing
Alarm
LED
LED
code
L26 -29
L30 - 33
0
0
Problems with water fill in wash phase
0
0
(maximum 10 minutes for each fill phase)
E11
0
0
1
1
0
0
Problems with water fill in drying phase
0
0
(maximum 10 minutes for each fill phase during
E12
0
1
in the wash load untangling phase)
1
0
0
0
Problems with water drain in wash phase
0
0
(maximum 10 minutes for each drain phase)
E21
1
0
0
1
Problems with water drain during drying or
0
0
drying condenser blocked
0
0
E22
1
1
(anti-boiling pressure switch closed
0
0
on "full")
0
0
Electronic pressure switch circuit faulty
0
0
(frequency of pressure switch signal out of
E31
1
0
limits)
1
1
Incorrect calibration of electronic pressure
0
0
switch (electronic pressure switch level different
0
0
E32
1
1
from 0-66 mm after initial calibration drain and
1
0
anti-boiling pressure switch on "empty")
Incongruence between level of electronic
0
0
pressure switch and level of anti-boiling
0
0
E33
1
1
pressure switch 1 (duration of fault at least 60
1
1
seconds)
Incongruence between level of electronic
0
0
pressure switch and level of anti-boiling
0
1
E34
1
0
pressure switch 2 (duration of fault at least 60
1
0
seconds)
Water level too high
0
0
(level of electronic pressure switch higher than
0
1
E35
1
0
300mm for more than 15 seconds)
1
1
SOI/DT 2002-03 eb
Description of fault
User
Effect
code
Cycle PAUSED Tap closed or mains pressure insufficient; solenoid
valve; hydraulic circuit of pressure switches;
E10
pressure switches; wiring; main PCB
Cycle PAUSED Tap closed or mains pressure insufficient; solenoid
valve; hydraulic circuit of pressure switches;
E10
pressure switches; wiring; main PCB
Cycle PAUSED Drain hose obstructed; filter blocked; drain pump;
pressure switches; wiring; main PCB
E20
Heating phase
Drain hose obstructed; filter blocked; drying
skipped
condenser blocked; drain pump; pressure switches;
E20
wiring; main PCB
Cycle blocked
Electronic pressure switch; wiring; main PCB
with door closed
---
Cycle PAUSED Tap closed or mains pressure insufficient; solenoid
valve; hydraulic circuit of pressure switches;
---
pressure switches; wiring; main PCB
Cycle blocked
Hydraulic circuit of pressure switches; electronic
with door closed
pressure switch; pressure switch; wiring; main PCB
---
Cycle blocked
Hydraulic circuit of pressure switches; electronic
with door closed
pressure switch; pressure switch; wiring; main PCB
---
Cycle blocked
Solenoid valve; hydraulic circuit of pressure
with door closed
switches; pressure switches; wiring; main PCB
---
and water drain
to 120mm
46
Possible causes
599 35 27-25