Circulation Pump; Heating; Drain Cycle - Electrolux AWF 1210 Service Manual

Washing machines & washer-dryers with ewm2000 electronic control
Table of Contents

Advertisement

5.6 Circulation pump

In Jetsystem models, the circulation pump is powered directly by the main PCB via a TRIAC.

5.7 Heating

The heating element is powered directly by the main PCB via a relay.
As a safety feature, a traditional dual-level pressure switch (anti-boiling 1 and anti-boiling 2) is connected in
series to the heating element.
The temperature is controlled directly by the main PCB via an NTC temperature sensor. Two versions of the
NTC sensor exist, depending on the type of tub; their shape is different, but their characteristics are
identical.
1. Plastic casing
2. Metallic capsule
3. NTC resistor
4. Terminals
1. NTC resistor
2. Metallic capsule
3. Terminals
4. Plastic casing
TEMPERATURE
(ºC)
20
60
80

5.8 Drain cycle

The drain pump is powered directly by the main PCB via a TRIAC.
TSE-P 02.00 EB
RESISTANCE (Ω)
Rated
Maximum
6050
1250
640
37/60
Minimum
6335
1278
620
5765
1222
660
599 35 24-30