Temperature Control; Calculating The Drying Time - Electrolux Washer Service Manual

Washing machines & washer-dryers with ewm2000evo electronic control
Table of Contents

Advertisement

11.1 Temperature control

The drying temperature is controlled by an NTC sensor positioned on the duct. The heater casing features
two safety thermostats (one of which is a manual-reset type).
1. Circuit board
2. Anti-boiling pressure switch AE1
3. Safety thermostat (auto-reset)
4. Drying heater
5. Safety thermostat (manual reset)
6. Anti-boiling pressure switch AE2
7. Fan motor
8. Drying control sensor (NTC)
9. Humidity control sensor (NTC)
1. Drying temperature control
2. Safety thermostat (auto reset)
3. Manual-reset safety
4. Drying heater
NTC sensor: resistance at 25°C
Manual-reset safety thermostat
Auto-reset safety thermostat
Heater
group
Fan capacity

Calculating the drying time:

In automatic cycles, the NTC sensor fitted to the drying condenser is used to calculate the drying time.
1. NTC temperature sensor
2. Tube from tub to condenser
3. Drying condenser
SOI/DT 2005-01 dmm
thermostat (NTC)
thermostat (150°C)
Power
Voltage
Resistance
5000Ω
Normally closed
Opens at 150°±5°C
Normally closed
Opens at 110°±3°C
Closes at 94°±5°
920+920 W
230V
56,5Ω+56,5Ω
3
80 m
– hour
49/65
240V
61,5Ω+61,5Ω
599 36 82-56