Bfm#8960] Number Of The Connected Modules; Bfm#9216] Number Of Ids Of Connected Modules; Bfm#9217 To #9344] Connected Module Id Information Storage Areas; Bfm#9984] Number Of The Alarm Ids - Mitsubishi Electric FX3U-128ASL-M User Manual

Melsec-f fx3u
Table of Contents

Advertisement

FX
-128ASL-M User's Manual
3U

7.3.11 [BFM#8960] Number of the connected modules

The number of slave modules detected by the automatic address detection is stored in BFM#8960.
BFM No.
hexa-
decimal
decimal
#8960
#2300H The number of slave modules is stored. (Up to 128 modules)

7.3.12 [BFM#9216] Number of IDs of connected modules

The number of IDs of connected modules is stored in BFM#9216 by the automatic address detection.
BFM No.
hexa-
decimal
decimal
#9216
#2400H The number of IDs of connected modules is stored. (Up to 128 IDs)

7.3.13 [BFM#9217 to #9344] Connected module ID information storage areas

Up to 128 IDs of connected slave modules are stored in ascending order in BFM#9217 to #9344.
The ID information is updated after the 128ASL-M is powered ON and the automatic address detection is
executed.
BFM No.
hexa-
decimal
decimal
#9217
#2401H
to
to
#9344
#2480H

7.3.14 [BFM#9984] Number of the alarm IDs

The number of IDs related to alarm occurrence is stored in BFM#9984.
BFM No.
hexa-
decimal
decimal
#9984
#2700H The number of IDs related to alarm occurrence is stored. (Up to 128 IDs)

7.3.15 [BFM#9985 to #10112] Alarm ID information storage areas

Up to 128 alarm IDs are stored in ascending order in BFM#9985 to #10112.
The ID information is updated after the 128ASL-M is powered ON and the automatic address detection is
executed.
BFM No.
hexa-
decimal
decimal
#9985
#2701H
to
to
#10112
#2780H
Connected module ID information is stored. (Up to 128 IDs)
IDs of all connected slave modules (BFM#9216) are stored in ascending order.
The IDs to be stored are as follows.
0000H to 007FH: ID of output slave modules
0200H to 027FH: ID of input slave modules or I/O combined slave modules
Alarm ID information is stored. (Up to 128 IDs)
IDs of all alarm slave modules (BFM#9984) are stored in ascending order.
The IDs to be stored are as follows.
0000H to 007FH: ID of output slave modules
0200H to 027FH: ID of input slave modules or I/O combined slave modules
Description
Description
Description
Description
Description
7 Buffer Memory
7.3 Details of buffer memory
Default
R/W
(decimal)
R
-
Default
R/W
(decimal)
R
-
Default
R/W
(decimal)
R
-
Default
R/W
(decimal)
R
0
Default
R/W
(decimal)
R
0
61
1
2
3
4
5
6
7
8
9
A

Advertisement

Table of Contents
loading

Table of Contents