Download Print this page

ADJ 7PZ IP User Instructions page 17

Hide thumbs Also See for 7PZ IP:

Advertisement

7PZ IP
Master-Slave Configuration:
This function will allows you to link units together to run in a Master-Slave
mode. In Master-Slave operation one unit will act as the controlling unit
and the others will react to the controlling units built-in programs. Any
unit can act as a Master or as a Slave however, only one unit can be pro-
grammed to act as the "Master."
Master-Slave Connections and Settings:
1. Daisy chain your units via the XLR connector on the rear of the unit.
Use standard XLR data cables to link your units together. Remember
that the Male XLR connector is the input and the Female XLR con-
nector is the ouput. The first unit in the chain (master) will use the
female XLR connector only. The last unit in the chain will use the
male XLR connector only.
2. Connect the first "Slave" unit to the "Master", and the "Slave" unit
should now start follow the "Master".
3. Set the "Master" unit to your desired mode of operation.
4. On the "Slave" units press the MODE button until "Menu Slave" is
displayed and press ENTER. The unit is now set as the "Slave"
unit. Each slave unit must be set to the same setting.
ADJ Products, LLC - www.adj.com - 7PZ IP User Manual Page 32
Master-Slave Configuration
7PZ IP
With this feature you are able to control the unit with DMX without the need
of XLR cables. Your DMX controller must be connected to a ADJ WiFly
TransCeiver to use this function. You are able to communicate up to 2500
feet/760 meters (open line of sight).
1. Turn on the WiFly function using the instructions on page 27.
2. Follow the instructions on page 26 to set the Wireless address. The
address must match the address set on the WiFly Transceiver.
3. After you have set the WiFly address, follow the DMX instructions on
pages 22-23 to select your desired DMX Channel mode and set your
DMX address.
4. Apply power to the ADJ WiFly Transceiver. The fixture must be set up
first before you apply power to WiFly Transceiver.
Note: If the sync does not work, switch the WiFly power off then on again.
7PZ IP
This feature will let you link units to run in a master-slave mode without the
use of XLR cables.
1. Follow the instructions on page 26 to set the Wireless address. The
addresses on each fixture must be the same.
2. After you have set the WiFly address, select your master unit and set
your desired operating mode.
3. Turn on the WiFly function using the instructions on page 27.
4. For the Slave units, put the unit in Slave mode. See page 32 Master-
Slave configuration when setting the unit as a Slave. Then switch ON the
WiFly power.
NOTE: If they do not sync up master-slave, switch the Master fixtures
WiFly off then on again.
ADJ Products, LLC - www.adj.com - 7PZ IP User Manual Page 33
WiFly Set Up
WiFly Master-Slave Set Up

Advertisement

loading