Dr 5 - Nominal Speed; Dr 5 - Time Basis For The Belt Speed - Siemens SIWAREX FTC Device Manual

Module for belt scale
Table of Contents

Advertisement

Name
Minimum belt loading
INT
Maximum belt loading
INT
Dyn. zero setting range
INT
Minimum belt loading
INT
for totalizing
Delay time for
TIME
monitoring the belt
loading / flow-rate at
start
Delay time for
TIME
monitoring the belt
loading / flow-rate in
operation
Totalizing value in WU
Totalizing value in LWU REAL
REAL
Quantity per pulse 1
Pulse duration 1 f.
TIME
Digital output
Minimum pause
TIME
duration 1 for digital
output
REAL
Quantity per pulse 2
Pulse duration 2 f.
TIME
Digital output
Minimum pause
TIME
duration 2 for digital
output
Overload-Undercut-
TIME
Inhibition time
Reserved
REAL
FIGURE 5-7
Defining belt scale parameter parameter
5.5.1
DR 5 – Nominal speed
The nominal speed of the belt corresponds with the speed at nominal
conditions, i.e. at nominal load on the belt. This is output in LU (length
units) per second e.g. 1.7 m/sec.
5.5.2
DR 5 – Time basis for the belt speed
The belt speed is output in LU (length units) per second. The measuring
time of the pulse input can be set to another time e.g. 2 seconds. That
5-52
SIWAREX FTC
Type
Address
Default
DBB048
DBB050
DBB052
DBW054
DBD056
DBB060
DBD064
REAL
DBD068
DBD072
DBD076
DBD080
DBD084
DBD088
DBD092
DBD096
DBW100
102
Range of Values / Meaning
Limit value for minimum belt loading in % of
the nominal belt loading
Limit value for maximum belt loading in % of
the nominal belt loading
Maximum belt loading with zero setting.
Limit value for minimum belt loading in % of
the nominal belt loading for totalizing
Delay time after switching on the belt until
monitoring the belt loading or flow-rate.
Delay time in continuous operation of the belt
until monitoring of the belt loading or flow-
rate.
0.1
Numeral step (‚Totalizing value') f. the
totalizing memory (Group 1) 1...4 in weight
unit WU
0.1
Numeral step (‚Totalizing value') f. the
totalizing memory (Group 2) 5...8 in large
weight unit LWU
0
Indicates, after which quantity increase for
group 1 that a pulse should be output (when
an external totalizing counter is connected))
Pulse duration 1 for outputting the required
0
quantity to a digital output (when an external
totalizing counter is connected 1)
(50 ....1000ms)
Minimum pause duration 1 for output of the
0
required quantity to digital output (when an
external totalizing counter is connected ) 50
....1000ms
0
Indicates, after which quantity increase that a
pulse should be output. (when an external
totalizing counter is connected 2)
Pulse duration group 2 for the output of the
0
required quantities to a digital output (when a
totalizing counter is connected)
50 ....1000ms
Minimum pause duration group 2 for output of
0
the required quantity to a digital output (when
a totalizing counter is connected)
50 ....1000ms
0
Time delay for the error messages which are
caused by overloading or undercutting the
measuring range
0
Reserved
Reference
5.5.14
5.5.15
5.5.16
5.5.17
5.5.18
5.5.19
5.5.20
5.5.21
5.5.22
5.5.23
5.5.24
5.5.25
5.5.26
5.5.27
5.5.28

Advertisement

Table of Contents
loading

Table of Contents