Dr3 Adjustment Parameters; Messages And Diagnosis - Siemens SIWAREX FTC Device Manual

Module for belt scale
Table of Contents

Advertisement

plausibility test corresponding with the defined operating mode. If there is a
parameter error then the data record will not be accepted (stored) by the
SIWAREX FTC and a "synchronous" message is generated (see chapter

Messages and Diagnosis

5.2 DR3 Adjustment Parameters

The adjustment parameters must be checked for each new scale and must be
changed where necessary and most important, the operating mode must be
defined during commissioning.
The scale is basically defined using the adjustment parameter and by performing
the adjustment. Adjusting the scale can be done using adjustment weights
5.2.1
(see
weighing machine, the data of the DR3 cannot be changed after calibration.
Procedures:
Check all parameters and change if necessary
o
Switch on service operation (command).
o
Send the DR3 to the scale
o
Perform scale adjustment
o
Receive DR3 from the scale
o
Switch off service operation
o
Name
(6) Adjustment
Adjustment digits for
DINT
Adjustment zero 0
Adjustment digits for
DINT
Adjustment weight 1
Adjustment digits for
DINT
adjustment weight 2
Adjustment digits for
DINT
Adjustment weight 3
Adjustment digits for
DINT
Adjustment weight 4
Adjustment weight 1
REAL
(Flow rate with bulk flow
measurement device)
adjustment weight 2
REAL
(Flow rate with bulk flow
measurement device)
Adjustment weight 3
REAL
(Flow rate with bulk flow
measurement device)
Adjustment weight 4
REAL
(Flow rate with bulk flow
measurement device)
5-32
SIWAREX FTC
).
5.3
) or theoretically (see
Type
Address
Default
DBD000
1398101
DBD004
15379113
DBD008
0
DBD012
0
DBD016
0
DBD020
50
DBD024
0
DBD028
0
DBD032
0
). In verifiable operation as a non-automatic
Range of Values / Meaning
24
0 to: 2
Other definitions not permitted.
24
0 to: 2
Other definitions not permitted.
24
0 to: 2
Other definitions not permitted.
24
0 to: 2
Other definitions not permitted.
24
0 to: 2
Other definitions not permitted.
> 0
Other definitions not permitted.
≥ 0
Other definitions not permitted.
≥ 0
Other definitions not permitted.
≥ 0
Other definitions not permitted.
7
Reference
5.2.1
5.2.1
5.2.1
5.2.1
5.2.1
5.2.1
5.2.1
5.2.1
5.2.1