5.5.20 DR 5 – Numeral step for totals 1...4
The totalizing memory 1...4 is run with the weight unit indicated in data
record 3. The user can define the smallest step for creating a total with the
numeral step.
E.g. weight unit 1 kg, numeral step for creating the total can be 5 kg.
5.5.21 DR 5 – Numeral step for the totals 4...5
Totalizing memory 4...8 is run with large weight unit indicated in data record
3. The user can define the smallest step for creating a total with the
numeral step.
E.g. Weight unit 1 kg, numeral step for totalizing can be 1 t.
5.5.22 DR 5 – Material quantity per pulse 1
The material quantity per pulse 1 indicates, after which quantity increase of
totalizing memory 1.....4 should output a pulse through the defined digital
output.
5.5.23 DR 5 – Pulse duration 1 for the digital output
For the external quantity counter, the pulse duration can be defined so that
the device can recognize the pulse for sure. The pulse duration is not
permitted to be selected so long that stopping the minimum pause duration
will make the next pulse late.
5.5.24 DR 5 – Minimum pause duration 1 for the digital output
For the external quantity counter, the pulse duration can be defined so that
the device can recognize the pulse for sure. The pulse duration is not
permitted to be selected so long that stopping the minimum pause duration
will make the next pulse late.
5.5.25 DR 5 – Material quantity per pulse 2
The material quantity per pulse 2 indicates, after which quantity increase of
totalizing memory 1.....4 1 should output a pulse through the defined digital
output.
5.5.26 DR 5 – Pulse duration 2 for the digital output
For the external quantity counter, the pulse duration can be defined so that
the device can recognize the pulse for sure. The pulse duration is not
permitted to be selected so long that stopping the minimum pause duration
will make the next pulse late.
5.5.27 DR 5 – Minimum pause duration 2 for the digital output
For the external quantity counter, the pulse duration can be defined so that
the device can recognize the pulse for sure. The pulse duration is not
permitted to be selected so long that stopping the minimum pause duration
will make the next pulse late.