Error
Data and operating
No.
errors
- Meaning
96
Tare T- invalid
97
98
Totalizing memory
already deleted
99
Distribution memory
could not be logged
100
Weight outside zero
definition range
101
Scale command
cannot be executed
since not at standstill
102
Adjustment weight
missing
105
Weighing operating
mode not allowed or
unknown
106
Limit values
implausible
111
Parameter
implausible for
external distribution
memory
112
Nominal speed
implausible.
113
Pulse constant
implausible.
114
115
Allocation of log text
No. for autom. logging
not permitted
116
Belt length
implausible
7-104 SIWAREX FTC
Explanation
The subtractive tare has been exceeded. This error is
generated in the following cases:
The gross value lies above the defined permitted tare
range for the taring command.
An externally defined tare value is negative.
An external defined tare value is larger than the maximum
value of weighing range 1 on a multi-resolution scale.
An externally define tare value is larger than the
maximum tare value [%] of the largest weighing range in
verifiable operation (technical regulation code OIML in DR
3) with a multi-resolution scale.
The Delete distribution memory command could not be
executed since the distribution memory is already zero
An error has occurred while logging the totalizing memory.
Check the output device. Check the additional technology
errors for indications concerning the cause of the error. A
technology fault is defined with the cause.
Zero definition cannot be executed since the current zero point
lies outside the zero definition range defined in DR 3 or the
current gross value lies above the largest defined weighing
range value. The limit value is defined in DR 5 with a loss-in-
weight scale.
The weighing command (Taring, Zero definition, Logging)
cannot be executed since the standstill is not within the
defined standstill time in DR 3.
Adjustment command cannot be executed because the
respective adjustment weight is not entered in DR 3.
Incorrect weighing operating mode in DR 3. Enter a correct
weighing operating mode.
The defined limit values in DR 4 are not plausible. Limit value
3 may only be operated as a max. limit value (On  Off).
Correct limit value 3.
At maximum flowrate, the pulses for the external summator
can not longer be output.
Nominal speed implausible
(must be larger than 0).
Pulse constant implausible
(must be larger than 0).
The log text number in DR 21 is incorrect. Correct the number
(0..4).
Effective belt length implausible
(must be larger than 0).