Dr 123 Data Content Mmc - Siemens SIWAREX FTC Device Manual

Module for belt scale
Table of Contents

Advertisement

Name
Filtered raw value
Net_Process
Belt load
Pulse counter value
Flowrate 1
Belt speed m/sec
Digital input states
Reserved
Current actuation signal
from controller in % *100
Setpoint value
Effective setpoint
Actuation signal according
to material characteristic
curve
Actuation signal according
to device characteristic
curve
Reserved
Table 5-26
Combination of recording elements
The evaluation of the collected data can be handled using SIWATOOL FTC and
MS Excel. All of the logged elements that have been recorded are stored in the
Excel table and can be read in a graph over time.
The progress of the weighing procedure can be analyzed and optimized.
In the event of sporadic events in the system, the recording can be activated as
circulating memory and can be ended with a condition in the SIMATIC control
program at any time. The subsequent evaluation can help to explain a sporadic
event in the system. A simultaneous evaluation of the message buffer, in which the
last 100 events are stored (evaluation with SIWATOOL FTC) offers a good basis
for an analysis or remote analysis.
An element requires 46 bytes. If the recording is run e.g. once per 50 msec, it
means memory requirements of 920 bytes per second.
In the simplest case, the RAM memory (approx. 2 MB) of the SIWAREX FTC can
be used for the recording.

5.26 DR 123 Data Content MMC

By reading the DR 122, SIWATOOL FTC can be used to determine which data is
stored on the Micro Memory Card. Based on this information, the user can read
targeted records and logs.
5-86
SIWAREX FTC
Length
Type
Range of Values / Meaning
bytes
DINT
4
Filtered digit value
REAL
4
Net weight
REAL
4
Current belt load WU/m
DINT
4
Pulse counter value with reference to the
measurement time
REAL
4
Flowrate [Weight/Time unit]
REAL
4
Belt speed
BYTE
1
Status of the DE
BYTE
1
Reserved
INT
2
Current actuation signal from controller in % *100
REAL
4
Setpoint value
REAL
4
Effective setpoint
REAL
4
Actuation signal according to material
characteristic curve
INT
2
Actuation signal according to device characteristic
curve
INT
2
Reserved
64
Reference

Advertisement

Table of Contents
loading