Power Inlet - Lab.gruppen PLM 20K44 Operation Manual

Plm plus series, powered loudspeaker management system
Hide thumbs Also See for PLM 20K44:
Table of Contents

Advertisement

8.5. Power Inlet

8.5.1 Power Connector
A Neutrik NAC3 Series powerCON connector rated at 32 A is fitted to the rear of the PLM+ for AC mains input.
The power cable (AC cord) supplied with the PLM+ has the mating connector ready-fitted, but may require a mains
(AC) plug specific to your country to be fitted to the other end. The wiring an pinout details are shown in Table 8.2.
powerCON pin
230 V Cable
L
N
Green/Yellow
Table 8.16: powerCON Connector Wiring and Pinout
115 V Cable
Brown
Black
Blue
White
Green
8. Back Panel Interface
PLM+ SERIES Operation Manual rev 3.0.1
67

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plm 12k44Plm 5k44

Table of Contents