Appendix; Faults And Warnings Overview - Lab.gruppen PLM 20K44 Operation Manual

Plm plus series, powered loudspeaker management system
Hide thumbs Also See for PLM 20K44:
Table of Contents

Advertisement

9. Appendix

9. Appendix

9.1. Faults and Warnings Overview

Category/Type
FRAME
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Fault
TEMP
Warning
Warning
Warning
Warning
Fault
Fault
68
PLM+ SERIES Operation Manual rev 3.0.1
Name
On screen text
CTRL OFFLINE
AES clock slipping
CLOCK SLIPPING
NAME CONFLICT
DANTE NEEDS
Dante module not detected
Dante module with
DANTE FW INVALID
Audio Fault
Sense fault DSP
A/D converter power
A/D PSU FAULT
supply fault
Temperature warning
TEMP WARN:PSU
power supply
Temperature warning
TEMP WARN:DSP
DSP area
Power supply
Temperature Limit
Amp channel
Temperature Limit
Temperature fault
power supply
Temperature fault
DSP area
Description
on the network
Frame not able to lock to
incoming AES stream
Two or more devices on the network
with the same Dante name
Lake cannot detect a functioning
SERVICE
Dante module
Dante module not loaded
with correct FW
Internal audio interface
AUDIO FAULT
not functioning
output faulty. Audio continues but
SENS FLT:DSP
protection might be compromised.
No load monitoring
Voltage supply to the analog input
converters faulty
Power supply temperature
approaching critical levels
DSP area temperature approaching
critical levels
PTL ACTIVE
to avoid power supply temp
fault protection
ATL ACTIVE
temp fault protection
Power supply temperature reached
TEMP FLT:PSU
internal protection limit
DSP area reached
TEMP FLT:DSP
critical temperature
Action
Check network cabling/
network if controller
expected on the network
Check AES sender and
Review Dante
Restart device; if not
cleared it needs service
to operate Dante
with LakeUpdate
Restart device; if not
cleared it needs service
Restart device; if not
cleared it needs service
Restart device; if not
cleared it needs service for
analog input to work
Improve cooling or reduce
output power to avoid
temperature becoming
critical
Improve cooling or reduce
output power to avoid
temperature becoming
critical
Improve cooling or reduce
output power to avoid
limiting
Improve cooling or reduce
output power to avoid
limiting
Automatically restarts
when cooled down
Improve cooling or
reduce power

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plm 12k44Plm 5k44

Table of Contents