Lab.gruppen PLM 20K44 Operation Manual page 19

Plm plus series, powered loudspeaker management system
Hide thumbs Also See for PLM 20K44:
Table of Contents

Advertisement

Table 5.3 shows the theoretical maximum output power for a given load impedance and ISVPL setting.
Max. Sinewave Burst Power (Watts)
LLoad Impedance (ohms)
LISVPL SETTING (V peak)
194
4489
193
4489
181
4489
167
4489
153
4489
121
3660
101
2550
83
1722
70
1225
56
784
47
552
38
361
17.8
Table 5.3: ISVPL–to–output examples
The ISVPL threshold may be set at any level between 17.8 V and 600 V in the Lake Controller software. For further
details, please refer to the Lake Controller User Manual.
Lake-enabled amplifier devices (D Series Lake, PLM+, PLM) that have a smaller peak output voltage capability still
allow ISVPL speaker threshold settings up to 600 V. When a threshold is set above the current maximum capability
of a power output channel, the actual ISVPL will automatically be set to the maximum ISVPL for that channel.
channel and displayed in [ ]. Therefore, the ISPVL threshold can be set at the Module for the speakers's maximum
capability, and the Module file remains cross-compatible with all Lake-enabled amplifier devices.
5.3.2. Current Peak Limiter (CPL)
The output Current Peak Limiter (CPL) ensures that the power output section will not be damaged by forcing it to
deliver current levels at the outputs that exceed the maximum current ratings of the output transistors. The CPL
keeps the output transistors within their Safe Operating Area (SOA). The CPL is non–adjustable.
This condition indicates an attempt to draw excessive current at the output. The output is attenuated until the
output current falls below the maximum current rating. Limiting is performed by the ISVPL limiter in conjunction
CPL activity is shown by red indication on the Power channel LED of the affected output channel and a
corresponding text description on the front panel in Lake Controller and CAFÉ software programs.
Refer to section 9.1 for more information on warnings and faults.
NOTE: If excessive current is indicated, check the output cables and examine the loudspeaker. If
impedance appears normal, you may rectify the condition by altering the ISVPL settings or lowering
input levels. CPL indication can be triggered by excessively low output impedance, possibly the result
of too many loudspeaker cabinets connected in parallel.
2
2.67
4
5993
4705
2352
5993
4656
2328
5993
4095
2048
5223
3486
1743
4384
2926
1463
2742
1830
915
1910
1275
638
1290
861
431
918
613
306
587
392
196
414
276
138
270
181
90
79
59
40
20
8
16
1176
1164
1024
872
732
458
319
215
153
98
69
45
10
PLM+ SERIES Operation Manual rev 3.0.1
5. Operation and performance
19