Meter Mode - Lab.gruppen PLM 20K44 Operation Manual

Plm plus series, powered loudspeaker management system
Hide thumbs Also See for PLM 20K44:
Table of Contents

Advertisement

7. Front Panel Interface

7.10. Meter Mode

7.10.1. Home View
The default view when powering on the device is Meter Mode > Home View as shown in Figure 7.7.
Figure 7.7: Meter Mode > Home View
Home View provides a summary of Module I/O gain level and limiter gain reduction, along with frame, module and
channel labeling information. The example in Figure 7.7 shows a mono 2-way, with Module A feeding power output
channels 1 & 2, and Module B configured as CL1-way feeding a subwoofer on power output channel 3.
Module C is configured for driving a full-range loudspeaker on power output 4. Module D is unused in this
example.
Module A label, input gain meter, faults, warnings, clips & mutes.
1
Module B label, input gain meter, faults, warnings, clips & mutes.
2
Module A label, input gain meter, faults, warnings, clips & mutes.
3
Module D label, input gain meter, faults, warnings, clips & mutes.
4
Module output label for Power channel 1, gain & sum of Lake MAX-Peak, MAX-RMS and ISVPL gain reduction
5
faults, warnings, clips & mutes.
Module output label for Power channel 2, gain & sum of Lake MAX-Peak, MAX-RMS and ISVPL gain reduction
6
faults, warnings, clips & mutes.
Module output label for Power channel 3, gain & sum of Lake MAX-Peak, MAX-RMS and ISVPL gain reduction
7
faults, warnings, clips & mutes.
Module output label for Power channel 4, gain & sum of Lake MAX-Peak, MAX-RMS and ISVPL gain reduction
8
faults, warnings, clips & mutes.
Menu Bar: Current View title & Frame label, Frame faults and warnings. The menu bar is located by default at
9
the top of the display, but can be configured in the front panel menu for placement at the bottom. The following
indications, as active or applicable, also are shown on the menu bar.
Ω
- AES3 Input Terminated (no icon = Unterminated)
- Analog Inputs Iso-Float Grounded (no icon = Floating)
- Dante Clock Master (no icon = Dante Slave or Dante Disabled)
- Dante Slave Only (no icon = device may be used as Dante Clock Master)
REDUNDANT - Dual Redundancy networking enabled. (No icon = configured for switch mode)
Please refer to Table 7.5 and Table 7.6 for full details on the faults and warnings that could be displayed in any of
the above locations.
42
PLM+ SERIES Operation Manual rev 3.0.1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plm 12k44Plm 5k44

Table of Contents