Indication Lights - SecEng SED-64 Installation & User Manual

3g alarm backup rev 4 (software 021)
Table of Contents

Advertisement

On board LED Indications
LED
1
2
3
4
5
6
FLT
7
BAT
8
ZFLT
9
OH
0
PWR
13 Fault Relay
14 Line Fault
15 AC
Fault LED Guide on Power up
If LED 6 (FLT) is flashing refer to the LED's as shown below
for the fault indication.
0
5
9
4
8
3
7
2
6
1
STATUS
SIGNAL

Indication Lights

Normal Operation
Signal level Low
Signal level Min
Signal level Med
Signal level Good
Signal level Best
GSM Fault
Low Battery
Zone unsealed
GSM Transmitting
Power On
Fault Relay
Telephone line not detected
AC OK
TEST
PWR
OH
ZONE FAULT
LOW BATT
PROG
FLT
In Programming mode
Indicates the digit 1
Indicates the digit 2
Indicates the digit 3
Indicates the digit 4
Indicates the digit 5
Indicates the digit 6
Indicates the digit 7
Indicates the digit 8
Indicates the digit 9
Indicates the digit 0
LED1 ON = GSM modem fault
LED2 ON = No Sim Card
LED3 ON = GSM signal or registration fault
LED4 ON = Not Applicable
LED5 ON = Not applicable
LED6 ON = GSM fault
LED8 ON = Zone 1 - 4 unsealed
1.4
8

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for SecEng SED-64

Table of Contents