SecEng SED-64 Installation & User Manual page 28

3g alarm backup rev 4 (software 021)
Table of Contents

Advertisement

6.3
Sed 64
4way I /O
Part :Sed 64 4 way I/O
Extra 4 relays and inputs
that can be multi chained
INSTALLATION PROCESS
1/ Power down the SED-64
2/ Fit Card as shown
3/ Fit 4 X 10k EOL into Inputs
4/ Power up
5/ Dip switches
volts
AC
Earth 16vac +Batt -
TESTING
The 4 zones can be tested thru and should come thru as zones
Point Number 258 to 261 see page 2.10 for details
Relays on this board are now controlled via SMS
Relay 1 = out5on
Relay 2 = out6on
Relay 3 = out7on
Relay 4 = out8on
See section 2.9 relay control for more functions
SED-64 Board options - 4 way I/O
Inputs x 4
Outputs x 4
STATUS
serial
WAKE
Line Fail LED
1
RS232
Volts
SED-64
This board allows for
an extra 4 inputs and 4 outputs
operating from the SED-64 v009
onwards
Part :SED 64 4-way I/O
SED 64
4-way I /O
prog
sim card holder
2
PWR
5
0
4
9
OH
3
8
ZONE FAULT
2
7
LOW BATT
1
6
FLT
STATUS
SIGNAL
NC C NO
C
1
2 C 3
4
FAULT
ZONE INPUTS
Inputs x 4
Outputs x 4
10 WAY
RIBBON
LEAD
TEST
PROG
28

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for SecEng SED-64

Table of Contents