3g alarm backup rev 4 (software 021)
Table of Contents

Advertisement

2.7
Function 17 - Zone Input configuration
Sets the operation of the 4 Zone Inputs on the SED-62/64
Option 0 = Zones 1-4 24 hour inputs
Option 1 = Zones 1-4 armed / disarmed via SMS
Option 2 = Zones 1-3 are 24 Hr but Zone 4 is a
control type and switches PSTN
over to GSM
Function 18 - SMS Zone Arming Confirmation
Enables confirmation SMS Message of arm / disarm
of Zones 1- 4 (Function 17 = 1) See Section 2.9 for
more details
Function 19 - Master Code
If you want to restrict access to the SED-62/64
programming. Enter a 4 digit PIN number.
You will have to then enter *19pin# before you can
reprogram or gain access to the SED-62/64 once set
(by either Manual Mode or SMS Programming Mode)
Once the *19pin# is entered it will allow you into
the programming mode for 5 minutes.
Function 24 - Fault Relay
Sets the operation of the Fault Relay
Option 0 = relay operates in normal mode
Option 1 = Inverts relay to operate in fail safe mode
Option 2 = Disables relay as fault relay and relay is
controlled via SMS as relay 0.
(see Section 2.9 for SMS output control)
Function 25 – I/O Expander Board
Enables the I/O expander board option. Only
enable this if an I/O expander board has been
plugged into the SED 61/62 only
Once fitted this provided a additional
4 inputs and 4 outputs
Default = 0
0 = Option 0
1 = Option 1
2 = Option 2
Example :
0 = Disabled
1 = Enabled
Example :
(SMS Confirmation Enabled)
Any 4 digit number
Example :
(Sets Master Code to 1234)
0 = Option 0
1 = Option 1
2 = Option 2
Example :
(Relay controlled by SMS)
61 62 only
0 = Disabled
1 = Enabled
Example :
(I/O Expander Board Enabled)
Options:
171#
*
Default = 0
Options:
181#
*
Default = Nil
Options:
191234#
*
Default = 0
Options:
242#
*
Default = 0
Options:
251#
*
16