Manual Programming Mode

Ensure the unit is powered up and working with no faults. Plug any standard
telephone handset (set to tone dialling) into the connector marked "CON1" on
the SED-64 Lift the handset and make sure you can hear a digital dial tone.
To enter program mode
Press and hold the PROG Button. When the PROG LED illuminates
followed by LED 1, release the program button. You are now in Program
mode.
Programming Example
Key into phone the following:
019999
This now has programmed the dialler
account code 9999 into function 01
To read function 01 back, key
flash 4 times indicating that 9999 is programmed in as the account code.
To exit program mode
Press and hold the PROG Button until LED 1 goes off, then release the
program button. The PROG LED should be off and the other LEDS will return
to normal.

SMS Programming Mode

To program the SED-64 using SMS from any mobile phone, Simply write a
text message in the format of
then send it to the SIM card mobile phone number in the SED-64
Attention : If the Master Code ( function 19) has been enabled, you must
first send
19????# (the ???? = Master Code) This will allow SMS
*
Programming Mode access for 5 minutes.
Example to program Function 01 client code = 9999 using SMS
Send the following text message
functions, just separate messages with a comma eg *01999#,*02134673#
Note: All SMS functions must start with a *(star) and end with a #(hash). Do
not use any spaces in between. This is the same as if you were programming
the SED-64 using manual mode programming.
5
4
3
2
1
SIGNAL
01
"Function No" "Option No"
019999 # to the SED-64 To program multiple
*
TEST
PWR
0
9
OH
8
ZONE FAULT
7
LOW BATT
PROG
6
FLT
STATUS
LED 1
Prog
Button
into the phone. LED 9 will
2.1
Prog
LED
2.2
and
10

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for SecEng SED-64

Table of Contents