SecEng SED-64 Installation & User Manual page 13

3g alarm backup rev 4 (software 021)
Table of Contents

Advertisement

2.4
Function 01 - client code
This sets the account code that the SED-62/64
will use when using its' on-board dialler to report
to the Monitoring Company.
Function 02 - Primary receiver number
This sets the primary phone number that the SED 62/64
will dial when using its' on-board dialler to report to the
Monitoring Company.
Note: Make sure the phone number can be
dialled from a mobile phone
Function 03 - Secondary receiver number
This sets the secondary phone number that the
SED 62/64 will dial when using its' on-board dialler
to report to the Monitoring Company if unable to
make a valid connection using the primary receiver
number.
Function 04 - GSM internal dialer test time
Change the time between the SED 62/64 test call
reports (sector 253). The time is in Hour intervals.
0 = No test call reports
24 = Test Call every DAY
168 = Test call once a week
To force a test call press and hold test button for 7 sec
test LED will flash, this will send a test call at the time
(see Section 2.8)
Function 05 - GSM Fail Relay trigger time
This sets the time between the SED-62/64 detecting
that the GSM signal is not present and when the fault
relay activates. This is important for times when the
GSM signal can occasionally drop out for short
periods but it is not necessary to send an alarm as it
restores within a few minutes.
Function 06 - PSTN Alarm delay
This sets the time between the SED-62/64 detecting that
the PSTN line voltage is low or not present and when a
PSTN trouble / fail alarm is reported. This is important
in areas where the PSTN line voltage can drop due to
loading but the line is still functional and restores normally.
Options:
Any 4 digit number
019999#
Example :
*
Options:
Any phone number up to
18 digits
021234567#
Example :
*
Options:
Any phone number
up to 18 digits
031234567#
Example :
*
Default = 24
Options:
From 0 to 168 Hours
Example :
(sets a test call every 24 hours)
Default = 8
Options:
From 1 to 8 minutes
Example :
(waits 5 minutes before the
Fault relay activates)
Default = 1
(30 seconds)
Options:
0 = 50 seconds
1 = 30 seconds
Example :
*
(50 secs before PSTN Fault activation)
(Daily)
0424#
*
minutes
055#
*
13
060#