SecEng SED-64 Installation & User Manual page 26

3g alarm backup rev 4 (software 021)
Table of Contents

Advertisement

6.1
1
2
RS232
Program PC
INSTALLING THE BOARD / Fit onto the SED-64 board into the position shown
on page 1.1a into the top 10 way connector on the SED-64 marked SERIAL
PROGAMMING
Connect any laptop or PC using a straight thru serial connection onto Serial 1
On the SED-64 this allows for programming and set up for the SED-64
Connect using HyperTerminal at 115k 8 N 1 to Port 1
Hit enter and password shall appear now type
You are now in the program mode Type ?S to see if you are in
SET UP PORT 2
With PC still connected, type the following:
CSDSPD=4800 (enter)
CSDRING=2
CSDEN=1
Now type ?CSDEN and the setting should be the same as you have just typed.
The SED-64 is now set up to receive circuit switched in-coming data calls
Wire up PORT 2 now to the TECOM TS 0091 as shown with lead provided
SED-64 Board option - Dual Serial
Dual
serial
Interface
TECOM TS 0091
SERIAL / PRINTER
INTERFACE
Tx
Rx
Port A
Cts
Rts
Gnd
Port B
(enter)
(enter)
This interface is used to allow
serial comms for the SED-64
Port 1 is used so you can
program the SED-64 via
HyperTerminal @115k 8N1
Port 2 is used for up load down
load via a circuit switched data
connection on the SIM card