The following SMS commands control additional features of the SED 62/64
NOTE
: SMS commands must be as shown. (MUST BE IN CAPITALS)
Zone Arm and Disarm feature
The SED 62/64 Zone Inputs can be armed or disarmed by sending the
following SMS Text Message. This command will arm/disarm all Zone Inputs.
Important: It is advisable to program functions 16,17 & 18 to Option 1, and
program the mobile numbers into function 12, 13 & 14 if necessary.
Arm / Disarm Commands
?ON = Arms all 4 zones
?OFF = Disarms all 4 zones (must be in capitals)
Zone Inputs Individual Text Labels
The SED 62/64 Zone Inputs can be programmed with individual text labels
for SMS reporting.
Text Message Format
in<State><Input><Text>
To Clear: send without <Text>
Example:
ina1front door will program Zone 1 alarm with "front door alarm" (MAX 10 CHAR)

Relay Control

To control the SED 62/64 Output Relays, send an SMS message as follows:
Text Message Format
out<Relay>on {Timer}
out<Relay>off {Timer}
Example (for Relay 5)
out5on
= Turns Relay 5 on
out5off
= Turns Relay 5 off
out5on2 = Turns Relay 5 on for 2 seconds
out5off2 = Turns relay 5 off for 30 seconds
Note: Relays 1 - 4 are via an expander board, which must be enabled in programming (see
function 25). Relay 5 is onboard as standard and Relay 0 can be enabled if the fault relay is
not required (see function 24).

SMS Commands

(must be in capitals)
Parameter Description:
<State> = "a" for alarm and "r" for restore
<Input> = Zone Input Number
<Text> = Max 10 Characters (including
spaces)
(indefinitely)
(indefinitely)
Parameter Description:
<Relay> = Relay Number
{Timer} = Optional timer value
in Hours [h] minutes [m] and
seconds
(if relay is off)
(if relay is on)