Sms Reports - SecEng SED-64 Installation & User Manual

3g alarm backup rev 4 (software 021)
Table of Contents

Advertisement

2.8
NOTE
: SMS commands must be as shown. (MUST BE IN CAPITALS)
From any GSM mobile phone, Simply send an SMS text message as
shown below to the SED-64 mobile phone number and it will send back
an SMS message with the requested report information.
Abc
158
?P
Options
Back
?S
?S
Send a
to request the current status of the SED-64. The current status
for the AC power, PSTN, Battery and GSM Signal Strength will be shown.
NOTE: If a Master Code has been set in the SED-64, you will not get a response from
any command (except for ?S). See Function 19 for information on the Master Code
setup.
?P
Send a ?P to request the current program function settings. See Section 2.3
for the list of function numbers and options.
?H
Send a ?H to request a list of the last 20 events that have occurred on the
SED-64. The first event listed is the oldest .
LEGEND
DT = GSM Dialer test
LB = Low battery
PF = AC Power fail
SF = GSM signal fail
LF = PSTN line fail
?T
When a ?T is sent to the SED-64 it will force a test call to the control room
and will reset the Test Call timer to start from this time. This can also be
done by holding the test button down for 10 seconds

SMS Reports

Available SED 62 SMS reports
?P = Request SED-64 program setup
?S = Request SED-64 current status
?H = Request History - Displays the last 20 events
?T= Force test call now to control room
i1 = input 1
TO = timed out
i2 = input 2
PB = program via button
i3 = input 3
PS = program via sms
i4 = input 4
iD = inputs disarm
DF = Dialer fail
iA = inputs armed
BF= battery fail
Gf = GSM fail
Ipr = fail ip address
?BT= boot
MCF = modem fail
17