Magtrol Model DSP7000 Dynamometer Controller
3.2.9
e
-C
DDy
urrenT
3.2.9.1
Hardware Connection
Torque/Speed
Conditioner
DES Power Supply
Figure 3–23 Eddy-Current Dynamometer with Powder Brake Dynamometer (Tandem Setup)
3.2.9.2
Software Configuration
1. Turn on the DSP7000 and proceed to the dynamometer configuration menu. See Section
3.2.1 – Dynamometer Configuration Menu.
2. Select PoWER UNITS until Wb is reached for TSC1.
3. Press MAx SPEED button and use and buttons and Decrease/Increase dial to set
desired scale factor.
4. Press SCALE I to add a filter if desired.
5. Press ShIFT to get to the TSC1 Eddy-Current Setup Menu. See Figure 3-16 TSC1 Eddy-
Current Setup Menu.
6. Press ToRqUE UNITS button and use and buttons and Decrease/Increase dial to set
desired max torque. Press SCALE P button use and buttons and Decrease/Increase
dial to set desired nominal speed. Press ShIFT 3 times to complete setup and return to the
main menu.
7. Press TSC to switch to TSC2 setup and proceed to the dynamometer configuration menu.
8. Select PoWER UNITS until Pb is reached for TSC2.
9. Press MAx SPEED button and use and buttons and Decrease/Increase dial to set
desired scale factor.
10. Press SCALE I to add a filter if desired.
11. Press ShIFT to get to the TSC2 Powder brake Setup Menu. See Figure 3-14 TSC2 Powder
Brake Setup Menu.
12. Press ToRqUE UNITS button and use and buttons and Decrease/Increase dial to set
desired max torque.
13. Press ShIFT 2 times. The menu will appear as shown in Figure 3–21 Tandem Setup Menu.
D
p
ynaMoMeTer wiTH
Powder Brake
Dynamometer (PB)
TSC 401
Torque
Excitation
7002
DSP
Dynamometer
Controller
Chapter 3 – Installation/Configuration
B
D
owDer
rake
ynaMoMeTer
Eddy-Current Brake
Dynamometer (WB)
Clutch
(EK)
Speed
Transformer
Torque
Excitation
31
(T
S
)
anDeM
eTup
TSC 401
Torque-Speed
Conditioner
DES Power Supply
PC
M-TEST
USB